English
Language : 

X9455 Datasheet, PDF (4/18 Pages) Intersil Corporation – Dual Two-wiper Digitally-Controlled (XDCP) Potentiometer
X9455
DC Electrical Specifications Over the recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
MAX
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL
SDA pin output LOW voltage
IOL = 3mA
VCC x 0.7
-1
VCC + 1
VCC x 0.3
0.4
UNITS
V
V
V
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNITS
Data changes per bit
Years
Capacitance
SYMBOL
TEST
CIN/OUT (Note 5) Input / Output capacitance (SDA)
CIN (Note 5) Input capacitance (DS0, DS1, CS, U/D, SCL, WP, A2, A1
and A0)
TEST CONDITIONS
VOUT = 0V
VIN = 0V
MAX
8
6
UNITS
pF
pF
Power-Up Timing
SYMBOL
PARAMETER
tD (Notes 5, 9) Power Up Delay from VCC power up (VCC above 2.7V) to wiper position recall
completed, and communication interfaces ready for operation.
MAX
2
UNITS
ms
A.C. Test Conditions
Input Pulse Levels
Input rise and fall times
Input and output timing threshold level
External load at pin SDA
2-Wire Interface Timing (s)
SYMBOL
PARAMETER
fSCL
Clock Frequency
tHIGH
Clock High Time
tLOW
Clock Low Time
tSU:STA Start Condition Setup Time
tHD:STA Start Condition Hold Time
tSU:STO Stop Condition Setup Time
tSU:DAT SDA Data Input Setup Time
tHD:DAT SDA Data Input Hold Time
tR (Note 5) SCL and SDA Rise Time
tF (Note 5) SCL and SDA Fall Time
tAA (Note 5) SCL Low to SDA Data Output Valid Time
tDH
SDA Data Output Hold Time
tIN (Note 5) Pulse Width Suppression Time at SCL and SDA inputs
tBUF (Note 5) Bus Free Time (Prior to Any Transmission)
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
2.3kΩ to VCC and 100 pF to VSS
MIN
600
1300
600
600
600
100
30
0
1200
MAX
400
300
300
0.9
50
UNITS
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
ns
ns
ns
4
FN8202.0
November 10, 2004