English
Language : 

X93156_07 Datasheet, PDF (4/7 Pages) Intersil Corporation – Single Digitally Controlled Potentiometer (XDCP™)
X93156
DC Electrical Specifications Over recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 9)
TYP
(Note 5)
MAX
(Note 9)
UNIT
ILI
CS input leakage current
VCC = 3V, CS = 0
60
100
150
µA
ILI
CS input leakage current
VCC = 5V, CS = 0
120
200
250
µA
ILI
INC, U/D input leakage current
VIN = VSS to VCC
±1
µA
VIH
CS, INC, U/D input HIGH voltage
VCC x 0.7
VCC + 0.5
V
VIL
CS, INC, U/D input LOW voltage
-0.5
VCC x 0.1
V
CIN
CS, INC, U/D input capacitance
(Notes 7, 8)
VCC = 3V, VIN = VSS, TA = +25°C, f = 1MHz
10
pF
NOTES:
2. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (VH(n)(actual)-VH(n)(expected)) = ±1 Ml Maximum.
n = 1.. 29 only
3. Relative linearity is a measure of the error in step size between taps = VH(n+1)—[VH(n) + Ml] = ±0.5 Ml, n = 1 .. 29 only.
4. 1 Ml = Minimum Increment = RTOT/31.
5. Typical values are for TA = +25°C and nominal supply voltage.
6. This parameter is periodically sampled and not 100% tested
7. This parameter is not 100% tested.
8. When performing multiple write operations, VCC must not decrease by more than 150mV from it’s initial value.
9. Parts are 100% tested at +25°C. Over-temperature limits established by characterization and are not production tested.
Endurance and Data Retention
PARAMETER
MIN
UNIT
Minimum endurance
200,000 Data changes per bit
Data retention
100
Years
Test Circuit #1
TEST POINT
VH/RH
Circuit #2 SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
AC Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
AC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
MIN
TYP
tCl
CS to INC setup
100
tlD
INC HIGH to U/D change
100
tDI
U/D to INC setup
100
tlL
INC LOW period
1
tlH
INC HIGH period
1
tlC
INC Inactive to CS inactive
1
tCPH
CS Deselect time (NO STORE)
250
tCPH
CS Deselect time (STORE)
10
tCYC
INC cycle time
2
MAX
UNIT
ns
ns
ns
µs
µs
µs
ns
ms
µs
4
FN8182.3
November 21, 2007