English
Language : 

X93156_07 Datasheet, PDF (3/7 Pages) Intersil Corporation – Single Digitally Controlled Potentiometer (XDCP™)
X93156
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, RH, RL and VCC
with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +6.5V
Maximum resistor current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2mA
Thermal Information
Thermal Resistance (Typical, Note 1)
θJA (°C/W)
8 Ld MSOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
190
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Temperature Range
Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage VCC
X93156xxx-2.7 . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V (Note 8)
X93156xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTE:
1. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
Potentiometer Specifications Over recommended operating conditions unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
MIN
(Note 9)
MAX
TYP (Note 9)
RTOT
End to end resistance
9.375
37.5
12.5 15.625
50
62.5
VR
RH, RL terminal voltages
Power rating
(Note 7)
0
VCC
1
Noise
Ref: 1kHz (Note 7)
-120
RW
Wiper Resistance
IW
Wiper Current
Resolution
(Note 6)
1100
±0.6
3
Absolute linearity (Note 2)
VH(n)(actual) - VH(n)(expected)
±1
(Note 4)
CH/CL/CW
Relative linearity (Note 3)
RTOTAL temperature coefficient
Potentiometer capacitances
VH(n + 1) - [VH(n) + MI] (Note 4)
(Note 7)
See circuit #2 (Note 7)
±0.5
±35
10/10/25
UNIT
kΩ
kΩ
V
mW
dBV
Ω
mA
%
MI
MI
ppm/°C
pF
DC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
(Note 9) (Note 5)
ICC1
VCC active current (Increment) CS = VIL, U/D = VIL or VIH and INC = 0.4V
50
@ max. tCYC VCC = 3V
CS = VIL, U/D = VIL or VIH and INC = 0.4V
200
@ max. tCYC VCC = 5V
ICC2
VCC active current (Store)
(EEPROM Store)
CS = VIH, U/D = VIL or VIH and INC =
VIH @ max. tWR VCC = 3V
CS = VIH, U/D = VIL or VIH and INC =
VIH @ max. tWR VCC = 5V
ISB
Standby supply current
CS = VCC - 0.3V, U/D and INC = VSS or
VCC - 0.3V VCC = 3V
CS = VCC - 0.3V, U/D and INC = VSS or
VCC - 0.3V VCC = 5V
ILI
CS input leakage current
VIN = VCC
MAX
(Note 9)
250
300
600
1400
1
2
±1
UNIT
µA
µA
µA
µA
µA
µA
µA
3
FN8182.3
November 21, 2007