Endurance and Data Retention
PARAMETER
MIN
UNIT
Minimum endurance
200,000 Data changes per bit
Data retention
100
Years
Test Circuit #1
Test Point
VH/RH
Circuit #2 SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
A.C. Conditions of Test
VL
Input pulse levels
0V to 5V
Input rise and fall times
10ns
Input reference levels
1.5V
AC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
MIN
TYP (6)
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tCYC
tR, tF(6)
tR VCC(6)
tWR
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC Inactive to CS inactive
CS Deselect time (NO STORE)
CS Deselect time (STORE)
INC cycle time
INC input rise and fall time
VCC power-up rate
Store cycle
100
100
100
1
1
1
250
10
2
1
5
Power Up and Down Requirements
There are no restrictions on the power-up or power-down
conditions of VCC and the voltages applied to the
potentiometer pins provided that VCC is always more
positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The
VCC ramp rate spec is always in effect.
MAX
500
10,000
10
UNIT
ns
ns
ns
µs
µs
µs
ns
ms
µs
µs
V/ms
ms
4
FN8181.1