Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, RH, RL and VCC
with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +6.5V
Lead temperature (soldering 10 seconds) . . . . . . . . . . . . . . . . 300°C
Maximum reflow temperature (40 seconds). . . . . . . . . . . . . . . 240°C
Maximum resistor current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2mA
Recommended Operating Conditions
Temperature Range
Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%(7)
CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; the functional
operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Potentiometer Specifications Over recommended operating conditions unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
MIN
TYP
MAX
UNIT
RTOT
VR
End to end resistance
RH, RL terminal voltages
Power rating
Noise
RTOTAL =50kΩ
Ref: 1kHz
37.5
0
50
-120
62.5
VCC
1
kΩ
V
mW(6)
dBV(6)
IR
CH/CL/CW
Potentiometer Current
Resolution
Absolute linearity(1)
Relative linearity(2)
RTOTAL temperature coefficient
Potentiometer capacitances
(5)
RH(n)(actual)-RH(n)(expected)
RH(n+1)-[RH(n)+MI]
(6)
See circuit #2
3
±35
10/10/25
0.6
±1
±0.5
mA
%
MI(3)
MI(3)
ppm/°C
pF(6)
Notes: (1) Absolute linearity is utilized to determine actual wiper resistance versus expected resistance = (RH(n)(actual)-RH(n)(expected)) = ±1
Ml Maximum. n = 1 .. 29 only
(2) Relative linearity is a measure of the error in step size between taps = RH(n+1)—[RH(n) + Ml] = ±0.5 Ml, n = 1 .. 29 only.
(3) 1 Ml = Minimum Increment = RTOT/31.
(4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested
(6) This parameter is not 100% tested.
(7) When performing multiple write operations, VCC must not decrease by more than 150mV from its initial value.
DC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP (4)
ICC1 VCC active current (Increment)
ICC2
ISB
VCC active current (Store)
(EEPROM Store)
Standby supply current
ILI
CS
ILI
CS
ILI
INC, U/D input leakage current
VIH CS, INC, U/D input HIGH voltage
VIL
CS, INC, U/D input LOW voltage
CIN(5)(7) CS, INC, U/D input capacitance
CS = VIL, U/D = VIL or VIH and
200
INC = 0.4V @ max. tCYC
CS = VIH, U/D = VIL or VIH and
INC = VIH @ max. tWR
CS = VCC - 0.3V, U/D and INC = VSS
or VCC - 0.3V
VCS = VCC
VCC = 5V, CS = 0
120
200
VIN = VSS to VCC
VCC x 0.7
-0.5
VCC = 5V, VIN = VSS, TA = 25°C,
f = 1MHz
MAX
300
1400
2.0
±1
250
±1
VCC + 0.5
VCC x 0.1
10
UNIT
µA
µA
µA
µA
µA
µA
V
V
pF
3
FN8181.1
September 26, 2005