English
Language : 

X93154 Datasheet, PDF (4/9 Pages) Intersil Corporation – Digitally Controlled Potentiometer
X93154
Endurance and Data Retention
PARAMETER
MIN
Minimum endurance
200,000
Data retention
100
UNIT
Data changes per bit
Years
Test Circuit #1
Test Point
VH/RH
Circuit #2 SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
A.C. Conditions of Test
Input pulse levels
0V to 3V
VL
Input rise and fall times
10ns
Input reference levels
1.5V
AC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
MIN
TYP(6)
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tCYC
tR, tF(7)
tR VCC(7)
tWR
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC Inactive to CS inactive
CS Deselect time (NO STORE)
CS Deselect time (STORE)
INC cycle time
INC input rise and fall time
VCC power-up rate
Store cycle
100
100
100
1
1
1
250
10
2
1.0
5
MAX
500
10,000
10
UNIT
ns
ns
ns
µs
µs
µs
ns
ms
µs
µs
V/ms
ms
Power Up and Down Requirements
There are no restrictions on the power-up or power-down
conditions of VCC and the voltages applied to the
A.C. Timing
potentiometer pins provided that VCC is always more
positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The
VCC ramp rate spec is always in effect.
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
(Store)
tCPH
90% 90%
10%
tF
tR
U/D
4
FN8180.2
October 5, 2005