English
Language : 

X93154 Datasheet, PDF (3/9 Pages) Intersil Corporation – Digitally Controlled Potentiometer
X93154
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, RH, RL and VCC
with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +6.5V
Lead temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . . 300°C
Maximum resistor current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2mA
Recommended Operating Conditions
Temperature Range
Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3V ±10%(8)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Potentiometer Specifications Over recommended operating conditions unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
MIN
TYP
MAX
UNIT
RTOT
VR
End to end resistance
RH, RL terminal voltages
Power rating
Noise
RTOTAL = 50kΩ
Ref: 1kHz
35
50
65
kΩ
0
VCC
V
1
mW(7)
-120
dBV(7)
RW
Wiper Resistance
(5) (6)
1000
Ω
IW
Wiper Current
(5) (6)
0.6
mA
Resolution
3
%
Absolute linearity(1)
Relative linearity(2)
VH(n)(actual)-VH(n)(expected)
VH(n+1)-[VH(n)+MI]
±1
±0.5
MI(3)
MI(3)
CH/CL/CW
RTOTAL temperature coefficient
Potentiometer capacitances
(7)
See circuit #3
±35
10/10/25
ppm/°C
pF(7)
NOTES:
1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (VH(n)(actual)-VH(n)(expected)) = ±1 Ml Maximum. n =
1 .. 29 only
2. Relative linearity is a measure of the error in step size between taps = VH(n+1)—[VH(n) + Ml] = ±0.5 Ml, n = 1 .. 29 only.
3. 1 Ml = Minimum Increment = RTOT/31.
4. Typical values are for TA = 25°C and nominal supply voltage.
5. This parameter is periodically sampled and not 100% tested
6. Typical values are for TA = 25°C and nominal supply voltage.
7. This parameter is not 100% tested.
8. When performing multiple write operations, VCC must not decrease by more than 150mV from its initial value.
DC Electrical Specifications Over recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP(4)
ICC1 VCC active current (Increment) CS = VIL, U/D = VIL or VIH and INC = 0.4V @
50
max. tCYC
ICC2
VCC active current (Store)
(EEPROM Store)
CS = VIH, U/D = VIL or VIH and INC = VIH @
max. tWR
ISB Standby supply current
CS = VCC - 0.3V, U/D and INC = VSS or
VCC - 0.3V
ILI
CS
VIN = VCC
ILI
CS
VCC = 3V, CS = 0
60
100
ILI
INC, U/D input leakage current VIN = VSS to VCC
VIH CS, INC, U/D input HIGH voltage
VCC x 0.7
VIL CS, INC, U/D input LOW voltage
-0.5
CIN(5)(7) CS, INC, U/D input capacitance VCC = 3V, VIN = VSS, TA = 25°C, f = 1MHz
MAX
250
600
1
±1
150
±1
VCC + 0.5
VCC x 0.1
10
UNIT
µA
µA
µA
µA
µA
µA
V
V
pF
3
FN8180.2
October 5, 2005