X80070, X80071, X80072, X80073
ELECTRICAL CHARACTERISTICS (Standard Settings) (Continued)
(Over the recommended operating conditions unless otherwise specified).
Symbol
Parameter
tFUV Undervoltage conditions to Gate Low
tFOV Overvoltage Conditions to Gate Low
tVFR Overvoltage/undervoltage failure re-
covery time to Gate =1V.
tBATT-ON Delay BATT-ON Valid
tMR Minimum time high for reset valid on
the MR pin
tMRE
Delay from MR enable to Gate Pin
LOW
tMRD Delay from MR disable to GATE
reaching 1V
tQC Delay from IGQ1 and IGQ0 to valid
Gate pin current
tSC_RETRY Delay between Retries
tNF Noise Filter for Overcurrent
tDPOR Device Delay before Gate assertion
Notes: (1) This parameter is based on characterization data.
Min.
0.5
1.0
1.2
5
1.0
1.8
90
4.5
45
Typ.
1.0
1.5
1.6
100
1.6
100
5
50
Max.
1.5
2
2
2.4
2.6
1
110
5.5
55
EQUIVALENT A.C. OUTPUT LOAD CIRCUIT
5V
Unit
Test Conditions
µs
µs
µs VDD does not drop below 3V,
No other failure conditions.
ns
µs
µs IGATE = 60µA, No Load
µs IGATE = 60µA, No Load
µs
ms
µs
ms
PWRGD
FAR
4.6kΩ
30pF
A.C. TEST CONDITIONS
Input pulse levels
Input rise and fall times
Input and output timing levels
Output load
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Standard output load
4
FN8150.0
March 15, 2005