English
Language : 

HCS14MS Datasheet, PDF (4/8 Pages) Intersil Corporation – Radiation Hardened HEX Inverting Schmitt Trigger
Specifications HCS14MS
TABLE 4. DC POST RADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETERS
Input Switch Points
SYMBOL
(NOTES 1, 2)
CONDITIONS
VT+
VCC = 4.5
VT-
VCC = 4.5
VH
VCC = 4.5
TEMPERATURE
+25oC
+25oC
+25oC
200K RAD LIMITS
MIN MAX UNITS
1.7
3.15
V
0.9
2.10
V
0.4
1.40
V
NOTES:
1. All voltages referenced to device GND.
2. AC measurements assume RL = 500Ω, CL = 50pF, Input TR = TF = 3ns, VIL = GND, VIH = VCC.
3. For functional tests, VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”.
TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25oC)
PARAMETER
GROUP B
SUBGROUP
DELTA LIMIT
ICC
5
3µA
IOL/IOH
5
-15% of 0 Hour
TABLE 6. APPLICABLE SUBGROUPS
GROUP A SUBGROUPS
CONFORMANCE GROUPS
MIL-STD-883 METHOD
TESTED FOR -Q
RECORDED FOR -Q
Initial Test
100% 5004
1, 7, 9
1 (Note 2)
Interim Test
100% 5004
1, 7, 9, ∆
1, ∆ (Note 2)
PDA
100% 5004
1, 7, ∆
Final Test
100% 5004
2, 3, 8A, 8B, 10, 11
Group A (Note 1)
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Subgroup B5
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11, ∆
1, 2, 3, ∆ (Note 2)
Subgroup B6
Sample 5005
1, 7, 9
Group D
Sample 5005
1, 7, 9
NOTES:
1. Alternate Group A testing in accordance with MIL-STD-883 Method 5005 may be exercised.
2. Table 5 parameters only.
TABLE 7. TOTAL DOSE IRRADIATION
CONFORMANCE
GROUPS
METHOD
TEST
PRE RAD
POST RAD
Group E Subgroup 2
5005
1, 7, 9
Table 4
NOTE:
1. Except FN test which will be performed 100% Go/No-Go.
READ AND RECORD
PRE RAD
POST RAD
1, 9
Table 4 (Note 1)
Spec Number 518752
4