English
Language : 

HC-5509B Datasheet, PDF (4/10 Pages) Intersil Corporation – SLIC Subscriber Line Interface Circuit
Specifications HC-5509B3999-003
Electrical Specifications
Unless Otherwise Specified, Typical Parameters are at TA = +25oC, Min-Max Parameters are Over
Operating Temperature Range, VB- = -48V, VB+ = +5V, AG = DG = BG = 0V. All AC Parameters are
specified at 600Ω 2-Wire Terminating Impedance. (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNITS
Ring Trip Detection Threshold
Ring Trip Detection Period
VRING = 105VRMS, fRING = 20Hz
-
10
-
mA
-
100
150
ms
Dial Pulse Distortion
-
0.1
0.5
ms
Relay Driver Outputs
On Voltage VOL
Off Leakage Current
TTL/CMOS Logic Inputs (F0, F1, RS, TEST, PRI)
IOL (PR) = 60mA, IOL (RD) = 30mA
VOH = 13.2V
-
0.2
0.5
V
-
±10
±100
µA
Logic ‘0’ VIL
Logic ‘1’ VIH
Input Current (F0, F1, RS, TEST, PRI)
Logic Outputs
0V ≤ VIN ≤ 5V
-
-
0.8
V
2.0
-
5.5
V
-
-
±100
µA
Logic ‘0’ VOL
Logic ‘1’ VOH
Power Dissipation On Hook
IB+
IB-
UNCOMMITED OP AMP PARAMETERS
ILOAD = 800µA
ILOAD = 40µA
Relay Drivers Off
VB+ = +5.25V, VB- = -58V, RLOOP = ∞
VB+ = +5.25V, VB- = -58V, RLOOP = ∞
-
0.1
0.5
V
2.7
-
-
V
-
200
-
mW
-
-
6
mA
-6
-
-
mA
Input Offset Voltage
-
±5
-
mV
Input Offset Current
-
±10
-
nA
Differential Input Resistance
(Note 3)
-
1
-
MΩ
Output Voltage Swing
Small Signal GBW
RL = 10kΩ
(Note 3)
-
±3
-
VP-P
-
1
-
MHz
NOTES:
1. Absolute maximum ratings are limiting values, applied individually, beyond which the serviceability of the circuit may be impaired.
Functional operability under any of these conditions is not necessarily implied.
2. May Be Extended to 1900Ω With Application Circuit.
3. These parameters are controlled by design or process parameters and are not directly tested. These parameters are characterized upon
initial design release, upon design changes which would affect these characteristics, and at intervals to assure product quality and
specification compliance.
4