English
Language : 

CD4514BMS Datasheet, PDF (4/9 Pages) Intersil Corporation – CMOS 4-Bit Latch/4-to-16 Line Decoders
Specifications CD4514BMS, CD4515BMS
TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
LIMITS
PARAMETER
Propagation Delay
Strobe or Datat
Propagation Delay
Inhibit
Transition Time
Minimum Data Setup
Time
Minimum Strobe Pulse
Width
Input Capacitance
SYMBOL
CONDITIONS
TPHL1 VDD = 10V
TPLH1 VDD = 15V
TPHL2 VDD = 10V
TPLH2 VDD = 15V
TTHL
TTLH
VDD = 10V
VDD = 15V
TS VDD = 5V
VDD = 10V
VDD = 15V
TW VDD = 5V
VDD = 10V
VDD = 15V
CIN Any Input
NOTES
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2
TEMPERATURE MIN
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
+25oC
-
MAX
370
270
220
170
100
80
150
70
40
250
100
75
7.5
UNITS
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
pF
NOTES:
1. All voltages referenced to device GND.
2. The parameters listed on Table 3 are controlled via design or process and are not directly tested. These parameters are characterized
on initial design release and upon design changes which would affect these characteristics.
3. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
TABLE 4. POST IRRADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS
LIMITS
PARAMETER
Supply Current
N Threshold Voltage
N Threshold Voltage
Delta
P Threshold Voltage
P Threshold Voltage
Delta
Functional
Propagation Delay Time
SYMBOL
CONDITIONS
IDD VDD = 20V, VIN = VDD or GND
VNTH VDD = 10V, ISS = -10µA
∆VTN VDD = 10V, ISS = -10µA
VTP
∆VTP
VSS = 0V, IDD = 10µA
VSS = 0V, IDD = 10µA
F
TPHL
TPLH
VDD = 18V, VIN = VDD or GND
VDD = 3V, VIN = VDD or GND
VDD = 5V
NOTES: 1. All voltages referenced to device GND.
2. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
NOTES
1, 4
1, 4
1, 4
TEMPERATURE MIN
+25oC
-
+25oC
-2.8
+25oC
-
1, 4
+25oC
0.2
1, 4
+25oC
-
1
1, 2, 3, 4
+25oC
+25oC
VOH >
VDD/2
-
3. See Table 2 for +25oC limit.
4. Read and Record
MAX
25
-0.2
±1
2.8
±1
VOL <
VDD/2
1.35 x
+25oC
Limit
UNITS
µA
V
V
V
V
V
ns
TABLE 5. BURN-IN AND LIFE TEST DELTA PARAMETERS +25oC
PARAMETER
SYMBOL
DELTA LIMIT
Supply Current - MSI-2
Output Current (Sink)
Output Current (Source)
IDD
IOL5
IOH5A
± 1.0µA
± 20% x Pre-Test Reading
± 20% x Pre-Test Reading
7-1191