English
Language : 

X60008E-50 Datasheet, PDF (3/14 Pages) Intersil Corporation – Precision 5.0V FGA Voltage Reference
X60008E-50
ABSOLUTE MAXIMUM RATINGS
Storage Temperature Range............ -65°C to + 125°C
Voltage on any Pin
Referenced to Gnd.............................-0.5V to + 10V
Voltage on “DNC” pins.........No connections permitted
to these pins.
Lead Temperature (soldering, 10 secs).......... + 225°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Industrial
Min.
-40°C
Max.
+85°C
COMMENT
Absolute Maximum Ratings indicate limits beyond
which permanent damage to the device and impaired
reliability may occur. These are stress ratings provided
for information only and functional operation of the
device at these or any other conditions beyond those
indicated in the operational sections of this specifica-
tion are not implied.
For guaranteed specifications and test conditions, see
Electrical Characteristics.
The guaranteed specifications apply only for the test
conditions listed. Some performance characteristics
may degrade when the device is not operated under
the listed test conditions.
ELECTRICAL CHARACTERISTICS
(Operating Conditions: VIN = 6.5V, IOUT = 0mA, COUT = 0.001µF, TA = -40 to +85°C unless otherwise specified.)
Symbol
Parameter
Conditions
Min Typ Max
Units
VOUT
VOA
Output Voltage
VOUT Accuracy
X60008EIS8-50
TA = 25°C
5.000
V
mV
-5.0
+5.0
IIN
VIN
TC VOUT
Supply Current
Input Voltage Range
Output Voltage
Temperature Coefficient(1)
X60008EIS8-50
500
800
nA
5.1
9.0
V
10
20
ppm/°C
∆VOUT/∆VIN
∆VOUT/∆IOUT
Line Regulation
Load Regulation
∆VOUT/∆t
∆VOUT/∆TA
VDO
ISC
VN
Long Term Stability
Thermal Hysteresis(2)
Dropout Voltage(3)
Short Circuit Current(4)
Output Voltage Noise
+5.5V ≤ VIN ≤ +8.0V
0mA ≤ ISOURCE ≤ 10mA
-10mA ≤ ISINK ≤ 0mA
TA = 25°C
∆T = -40°C to +85°C
IOUT = 5mA, ∆VOUT = 0.01%
TA = 25°C
0.1Hz to 10Hz
150
µV/V
15
50
µV/mA
25
100
10
ppm/
1000Hrs
50
ppm
150
300
mV
50
80
mA
30
µVpp
Note:
1. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in VOUT is divided
by the temperature range; in this case, -40°C to +85°C = 125°C.
2. Thermal Hysteresis is the change in VOUT created by package stress @ TA = 25°C after temperature cycling. VOUT is read initially at TA
= 25°C; the X60008 is then cycled between Hot (85°C) and Cold (-40°C) before a second VOUT measurement is taken at 25°C. The
deviation between the initial VOUT reading and the second VOUT reading is then expressed in ppm.
3. Dropout voltage (VDO) is the minimum voltage (VIN) into the X60008 which will produce the output voltage (∆VOUT) drop specified in the
Electrical Characteristics table.
4. Guaranteed by Device Characterization
3
FN8145.0
March 14, 2005