English
Language : 

CD54AC02F3A Datasheet, PDF (3/4 Pages) Intersil Corporation – Quad 2-Input NOR Gate
CD54AC02F3A, CD54ACT02F3A
DC Electrical Specifications (Continued)
PARAMETER
Low Level Output Voltage
SYMBOL
VOL
TEST
CONDITIONS
VI (V)
VIH or VIL
IO (mA)
0.05
0.05
VCC
(V)
1.5
3
25oC
MIN
MAX
-
0.1
-
0.1
-55oC TO 125oC
MIN
MAX
-
0.1
-
0.1
UNITS
V
V
0.05
4.5
-
0.1
-
0.1
V
12
3
-
0.36
-
0.5
V
24
4.5
-
0.36
-
0.5
V
(Note 5)
(Note 5)
50
5.5
-
-
-
1.65
V
(Note 6, 7)
Input Leakage Current
II
VCC or
-
5.5
-
±0.1
-
±1
µA
GND
(Note 5)
(Note 5)
Quiescent Device Current
ICC
0
5.5
-
4
-
80
µA
(Note 5)
(Note 5)
ACT TYPES
High Level Input Voltage
VIH
-
-
4.5 to 5.5
2
-
2
-
V
(Note 5)
(Note 5)
Low Level Input Voltage
VIL
-
-
4.5 to 5.5
-
0.8
-
0.8
V
(Note 5)
(Note 5)
High Level Output Voltage
VOH
VIH or VIL -0.05
4.5
4.4
-
4.4
-
V
-24
4.5
3.94
-
3.7
-
V
(Note 5)
(Note 5)
-50
5.5
-
(Note 6, 7)
-
3.85
-
V
Low Level Output Voltage
VOL
VIH or VIL
0.05
4.5
24
4.5
-
0.1
-
0.1
V
-
0.36
-
0.5
V
(Note 5)
(Note 5)
50
5.5
-
-
-
1.65
V
(Note 6, 7)
Input Leakage Current
II
VCC or
-
5.5
-
±0.1
-
±1
µA
GND
(Note 5)
(Note 5)
Quiescent Device Current
ICC
VCC or
0
5.5
-
4
-
80
µA
GND
(Note 5)
(Note 5)
Additional Supply Current per ∆ICC
VCC
-
4.5 to 5.5
-
2.4
-
Input Pin TTL Inputs High
-2.1
1 Unit Load
3
mA
NOTES:
5. Tested at 100%.
6. Test one output at a time for a 1-second maximum duration. Measurement is made by forcing current and measuring voltage to minimize
power dissipation.
7. Test verifies a minimum transmission-line-drive capability of 75Ω for 54AC/ACT Series.
ACT Input Load Table
INPUT
UNIT LOAD
All
0.32
NTaObTleE, :e.Ug.n,i2t l.o4amdAism∆aICxCatlim25itosCp.ecified in DC Electrical Specifications
3