D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
ICC2
ISB
Parameter
VCC supply current
(active)
VCC supply current
(nonvolatile write)
VCC current (standby)
ILI
ILO
VIH
VIL
VOL
VOH
VOH
Input leakage current
Output leakage current
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Output HIGH voltage
Output HIGH voltage
Min.
Limits
Typ. Max.
400
1
5
5
VCC x 0.7
-1
VCC - 0.8
VCC - 0.4
10
10
VCC + 1
VCC x 0.3
0.4
Units
μA
mA
μA
μA
μA
V
V
V
V
V
Test Conditions
fSCK = 2.5 MHz, SO = Open, VCC = 6V
Other Inputs = VSS
fSCK = 2.5MHz, SO = Open, VCC = 6V
Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS,
CS = VCC = 6V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
IOH = -1mA, VCC ≥ +3V
IOH = -0.4mA, VCC ≤ +3V
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Units
Data changes per bit per register
years
CAPACITANCE
Symbol
COUT(6)
CIN(6)
Test
Output capacitance (SO)
Input capacitance (A0, A1, SI, CS, WP, HOLD, and SCK)
Max.
8
6
Units
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
POWER-UP TIMING
Symbol
tr VCC(6)
tPUR(7)
Parameter
VCC Power-up rate
Power-up to initiation of read operation
Min.
0.2
Max.
50
1
Units
V/ms
ms
POWER-UP AND DOWN REQUIREMENTS
The are no restrictions on the sequencing of the bias supplies VCC, V+, and V- provided that all three supplies reach
their final values within 1msec of each other. At all times, the voltages on the potentiometer pins must be less than V+
and more than V-. The recall of the wiper position from nonvolatile memory is not in effect until all supplies reach their
final value. The VCC ramp rate spec is always in effect.
A.C. TEST CONDITIONS
Input Pulse Levels
Input rise and fall times
VCC x 0.1 to VCC x 0.9
10ns
Input and output timing level
VCC x 0.5
Notes: (6) This parameter is not 100% tested
(7) tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued.
These parameters are not 100% tested.