English
Language : 

HC5523 Datasheet, PDF (14/18 Pages) Intersil Corporation – LSSGR/TR57 CO/Loop Carrier SLIC with Low Power Standby
HC5523
SLIC Operating States
E0
E1
C1
C2
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
TABLE 1. LOGIC TRUTH TABLE
SLIC OPERATING STATE
ACTIVE DETECTOR
Open Circuit
No Active Detector
Active
Ground Key Detector
Ringing
No Active Detector
Standby
Ground Key Detector
DET OUTPUT
Logic Level High
Ground Key Status
Logic Level High
Ground Key Status
0
1
0
0
Open Circuit
0
1
0
1
Active
0
1
1
0
Ringing
0
1
1
1
Standby
No Active Detector
Loop Current Detector
Ring Trip Detector
Loop Current Detector
Logic Level High
Loop Current Status
Ring Trip Status
Loop Current Status
1
0
0
0
Open Circuit
1
0
0
1
Active
1
0
1
0
Ringing
1
0
1
1
Standby
1
1
0
0
Open Circuit
1
1
0
1
Active
1
1
1
0
Ringing
1
1
1
1
Standby
The fuse resistors (RF) serve a dual purpose of being
nondestructive power dissipaters during surge and fuses
when the line in exposed to a power cross.
Power-Up Sequence
The HC5523 has no required power-up sequence. This is a
result of the Dielectrically Isolated (DI) process used in the
fabrication of the part. By using the DI process, care is no
longer required to insure that the substrate be kept at the
most negative potential as with junction isolated ICs.
Printed Circuit Board Layout
Care in the printed circuit board layout is essential for proper
operation. All connections to the RSN pin should be made as
close to the device pin as possible, to limit the interference
that might be injected into the RSN terminal. It is good
practice to surround the RSN pin with a ground plane.
The analog and digital grounds should be tied together at
the device.
Notes
2. Overload Level (Two-Wire port) - The overload level is speci-
fied at the 2-wire port (VTR0) with the signal source at the 4-
wire receive port (ERX). IDCMET = 30mA, RSG = 4kΩ, increase
the amplitude of ERX until 1% THD is measured at VTRO. Ref-
erence Figure 1.
3. Longitudinal Impedance - The longitudinal impedance is
computed using the following equations, where TIP and RING
voltages are referenced to ground. LZT, LZR, VT, VR, AR and AT
are defined in Figure 2.
No Active Detector
Ground Key Detector
No Active Detector
Ground Key Detector
No Active Detector
Loop Current Detector
Ring Trip Detector
Loop Current Detector
Logic Level High
(TIP) LZT = VT/AT
(RING) LZR = VR/AR
where: EL = 1VRMS (0Hz to 100Hz)
4. Longitudinal Current Limit (Off-Hook Active) - Off-Hook
(Active, C1 = 1, C2 = 0) longitudinal current limit is determined
by increasing the amplitude of EL (Figure 3A) until the 2-wire
longitudinal balance drops below 45dB. DET pin remains low
(no false detection).
5. Longitudinal Current Limit (On-Hook Standby) - On-Hook
(Active, C1 = 1, C2 = 1) longitudinal current limit is determined
by increasing the amplitude of EL (Figure 3B) until the 2-wire
longitudinal balance drops below 45dB. DET pin remains high
(no false detection).
6. Longitudinal to Metallic Balance - The longitudinal to metal-
lic balance is computed using the following equation:
BLME = 20 • log (EL/VTR), where: EL and VTR are defined in
Figure 4.
7. Metallic to Longitudinal FCC Part 68, Para 68.310 - The
metallic to longitudinal balance is defined in this spec.
8. Longitudinal to Four-Wire Balance - The longitudinal to 4-wire
balance is computed using the following equation:
BLFE = 20 • log (EL/VTX),: EL and VTX are defined in Figure 4.
9. Metallic to Longitudinal Balance - The metallic to longitudi-
nal balance is computed using the following equation:
BMLE = 20 • log (ETR/VL), ERX = 0
where: ETR, VL and ERX are defined in Figure 5.
10. Four-Wire to Longitudinal Balance - The 4-wire to longitudi-
nal balance is computed using the following equation:
BFLE = 20 • log (ERX/VL), ETR = source is removed.
where: ERX, VL and ETR are defined in Figure 5.
11. Two-Wire Return Loss - The 2-wire return loss is computed
using the following equation:
69