English
Language : 

X9258_11 Datasheet, PDF (12/20 Pages) Intersil Corporation – Quad Digital Controlled Potentiometers(XDCP™)
X9258
DC Operating Characteristics Over recommended operating conditions, unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 8)
TYP
MAX
(Note 8)
UNIT
ICC1
VCC Supply Current (Nonvolatile
Write)
fSCL = 400kHz, SDA = Open,
Other Inputs = VSS
1
mA
ICC2
VCC Supply Current (Move Wiper, fSCL = 400kHz, SDA = Open,
Write, Read)
Other Inputs = VSS
100
µA
ISB
VCC Current (Standby)
SCL = SDA = VCC, Addr. = VSS
5
µA
ILI
Input Leakage Current
VIN = VSS to VCC
10
µA
ILO
Output Leakage Current
VOUT = VSS to VCC
10
µA
VIH
Input HIGH Voltage
VCC x 0.7
VCC + 0.1
V
VIL
Input LOW Voltage
-0.5
VCC x 0.3
V
VOL Output LOW Voltage
IOL = 3mA
0.4
V
NOTES:
9. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
10. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentiometer. It is
a measure of the error in step size.
11. MI = RTOT/255 or (VH/RH—VL/RL)/255, single potentiometer.
12. Max = all four arrays cascaded together; typical = individual array resolutions.
Endurance and Data Retention
PARAMETER
Minimum Endurance
Data Retention
MIN
(Note 8)
100,000
100
UNIT
Data changes per bit per register
years
Capacitance
SYMBOL
PARAMETER
CI/O (Note 13) Input/Output Capacitance (SDA)
CIN (Note 13) Input Capacitance (A0, A1, A2, A3, and SCL)
TEST CONDITIONS
VI/O = 0V
VIN = 0V
MAX
(Note 8)
8
6
UNIT
pF
pF
Power-Up Timing
SYMBOL
PARAMETER
MIN
(Note 8)
MAX
(Note 8)
UNIT
tPUR (Note 14) Power-up to Initiation of Read Operation
1
ms
tPUW (Note 14) Power-up to Initiation of Write Operation
5
ms
tR VCC (Note 15) VCC Power-up Ramp
0.2
50
V/ms
NOTES:
13. This parameter is periodically sampled and not 100% tested.
14. tPUR and tPUW are the delays required from the time the third (last) power supply (VCC, V+ or V-) is stable until the specific instruction can be
issued. These parameters are periodically sampled and not 100% tested.
15. Sample tested only.
12
FN8168.5
April 14, 2011