X9400 Datasheet, PDF (11/21 Pages) Xicor Inc. – Quad Digitally Controlled Potentiometers (XDCP)
X9400
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
ICC2
ISB
ILI
ILO
VIH
VIL
VOL
Parameter
VCC supply current (Active)
VCC supply current (Nonvolatile
Write)
VCC current (standby)
Input leakage current
Output leakage current
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Min.
VCC x 0.7
-0.5
Limits
Typ. Max.
400
Units
µA
1
mA
1
µA
10
µA
10
µA
VCC + 0.5 V
VCC x 0.1 V
0.4
V
Test Conditions
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per bit per register
years
CAPACITANCE
Symbol
COUT(4)
CIN(4)
Test
Output capacitance (SO)
Input capacitance (A0, A1, SI, and SCK)
POWER-UP TIMING
Symbol
tPUR(5)
tPUW(5)
tR VCC(4)
Parameter
Power-up to initiation of read operation
Power-up to initiation of write operation
VCC Power-up ramp
POWER-UP REQUIREMENTS (Power-up sequencing
can affect correct recall of the wiper registers)
The preferred power-on sequence is as follows: First
VCC, then the potentiometer pins, RH, RL, and RW.
Voltage should not be applied to the potentiometer
pins before V+ or V- is applied. The VCC ramp rate
specifi-cation should be met, and any glitches or slope
changes in the VCC line should be held to <100mV if
possible. If VCC powers down, it should be held below
0.1V for more than 1 second before powering up again
in order for proper wiper register recall. Also, VCC
should not reverse polarity by more than 0.5V. Recall
of wiper position will not be complete until VCC, V+
and V-reach their final value.
Max.
8
6
Unit
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
Min.
0.2
Max.
1
5
50
Unit
ms
ms
V/msec
EQUIVALENT A.C. LOAD CIRCUIT
SDA Output
5V
1533Ω
100pF
11
FN8189.1
March 31, 2005