English
Language : 

X9400 Datasheet, PDF (10/21 Pages) Xicor Inc. – Quad Digitally Controlled Potentiometers (XDCP)
X9400
ABSOLUTE MAXIMUM RATINGS
Temperature under bias..................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on SCK, SCL or any address
input with respect to VSS......................... -1V to +7V
Voltage on V+ (referenced to VSS) ........................ 10V
Voltage on V- (referenced to VSS) ........................-10V
(V+) - (V-)............................................................... 12V
Any VH ....................................................................V+
Any VL ...................................................................... V-
Lead temperature (soldering, 10 seconds)........ 300°C
IW (10 seconds)................................................±12mA
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Min.
0°C
-40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification)
is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Device
X9400
X9400-2.7
Supply Voltage (VCC) Limits
5V ± 10%
2.7V to 5.5V
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
RTOTAL
IW
RW
Parameter
End to end resistance
Power rating
Wiper current
Wiper resistance
Vv+
Vv-
VTERM
CH/CL/CW
IAL
Voltage on V+ Pin X9400
X9400-2.7
Voltage on V- Pin X9400
X9400-2.7
Voltage on any VH/RH or VL/RL Pin
Noise
Resolution
Absolute linearity (1)
Relative linearity (2)
Temperature coefficient of RTOTAL
Ratiometric temp. coefficient
Potentiometer capacitances
RH, RL, RW leakage current
Min.
+4.5
+2.7
-5.5
-5.5
V-
-1
-0.2
Limits
Typ. Max.
±20
50
±6
150
250
40
100
-120
1.6
±300
10/10/25
0.1
+5.5
+5.5
-4.5
-2.7
V+
+1
+0.2
±20
10
Unit
%
mW
mA
Ω
Ω
V
Test Conditions
25°C, each pot
Wiper Current = ± 1mA,
VCC = 3V
Wiper Current = ± 1mA,
VCC = 5V
V
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/°C
pF
µA
Ref: 1kHz
Rw(n)(actual) - Rw(n)(expected)
Rw(n + 1) - [Rw(n) + MI]
See Spice Macromodel
VIN = VSS to VCC. Device is in
stand-by mode.
Notes: (1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when
used as a potentiometer.
(2) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (RH - RL)/63, single pot
10
FN8189.1
March 31, 2005