English
Language : 

X9401_09 Datasheet, PDF (10/18 Pages) Intersil Corporation – Quad, 64 Tap, Digitally Controlled Potentiometer (XDCP™)
X9401
Absolute Maximum Ratings
Supply Voltage (VCC Limits)
X9401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ±10%
X9401-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Voltage on SCK, SCL or any address input
with respect to VSS: . . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
ΔV = |(VH–VL)| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5V
Thermal Information
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Operating Conditions
Temperature Range
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
Analog Specifications (Over recommended operating conditions unless otherwise stated.)
SYMBOL
PARAMETER
TEST CONDITION
MIN
(Note 10)
TYP
MAX
(Note 10) UNIT
RTOTAL
End to End resistance Tolerance
Power Rating
+25°C, each pot
-20
+20
%
50
mW
IW
RW
VTERM
Wiper Current
Wiper Resistance
Voltage on any VH or VL Pin
Noise
IW = (VH - VL)/RTOTAL VCC = 5V
Ref: 1kHz
-6
+6
mA
150
500
Ω
VSS
VCC
V
-120
dBV
Resolution
1.6
%
Absolute Linearity (Note 7)
VW(n)(actual) - VW(n)(expected)
-1
+1
MI
(Note 9)
Relative Linearity (Note 8)
Vw(n+1) - [Vw(n)+ MI]
-0.2
+0.2
MI
(Note 9)
Temperature Coefficient of RTOTAL
Ratiometric Temperature Coefficient
V(RH) = VCC, V(RL) = VSS
±300
±20
ppm/°C
ppm/°C
CH/CL/CW Potentiometer Capacitances
See Macro model
10/10/25
pF
IAL
RH, RL, RW Leakage Current
VIN = VSS Device is in Stand-by mode.
0.1
10
µA
NOTES:
7. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
8. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentiometer. It is
a measure of the error in step size.
9. MI = RTOT/63 or (VH - VL)/63, single pot.
10. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by
characterization and are not production tested.
Power-up and Down Requirements
The are no restrictions on the power-up or power-down
conditions of VCC and the voltages applied to the poten-
tiometer pins provided that VCC is always more positive than
or equal to VH, VL, and VW, i.e., VCC ≥ VH, VL, VW.
The VCC power-up spec is always in effect.
10
FN8190.4
October 13, 2009