HI7190_06 Datasheet, PDF (1/25 Pages) Intersil Corporation – 24-Bit, High Precision, Sigma Delta A/D Converter | |||
|
®
Data Sheet
June 27, 2006
HI7190
FN3612.10
24-Bit, High Precision, Sigma Delta A/D
Converter
The Intersil HI7190 is a monolithic instrumentation, sigma
delta A/D converter which operates from ±5V supplies. Both
the signal and reference inputs are fully differential for
maximum flexibility and performance. An internal
Programmable Gain Instrumentation Amplifier (PGIA)
provides input gains from 1 to 128 eliminating the need for
external pre-amplifiers. The on-demand converter auto-
calibrate function is capable of removing offset and gain
errors existing in external and internal circuitry. The on-board
user programmable digital filter provides over 120dB of
60/50Hz noise rejection and allows fine tuning of resolution
and conversion speed over a wide dynamic range. The
HI7190 and HI7191 are functionally the same device, but the
HI7190 has tighter linearity specifications.
The HI7190 contains a serial I/O port and is compatible with
most synchronous transfer formats including both the
Motorola 6805/11 series SPI and Intel 8051 series SSR
protocols. A sophisticated set of commands gives the user
control over calibration, PGIA gain, device selection, standby
mode, and several other features. The On-chip Calibration
Registers allow the user to read and write calibration data.
Pinout
HI7190
20 LD SOIC, PDIP
TOP VIEW
SCLK 1
SDO 2
SDIO 3
CS 4
DRDY 5
DGND 6
AVSS 7
VRLO 8
VRHI 9
VCM 10
20 MODE
19 SYNC
18 RESET
17 OSC1
16 OSC2
15 DVDD
14 AGND
13 AVDD
12 VINHI
11 VINLO
Features
⢠22-Bit Resolution with No Missing Code
⢠0.0007% Integral Non-Linearity (Typ)
⢠20mV to ±2.5V Full Scale Input Ranges
⢠Internal PGIA with Gains of 1 to 128
⢠Serial Data I/O Interface, SPI Compatible
⢠Differential Analog and Reference Inputs
⢠Internal or System Calibration
⢠120dB Rejection of 60/50Hz Line Noise
⢠Settling Time of 4 Conversions (Max) for a Step Input
⢠Pb-Free Plus Anneal Available (RoHS Compliant)
Applications
⢠Process Control and Measurement
⢠Industrial Weight Scales
⢠Part Counting Scales
⢠Laboratory Instrumentation
⢠Seismic Monitoring
⢠Magnetic Field Monitoring
⢠Additional Reference Literature
- Technical Brief, TB348 âHI7190/1 Negative Full Scale
Error vs Conversion Frequencyâ
- Application Note, AN9504 âA Brief Intro to Sigma Delta
Conversionâ
- Technical Brief, TB329 âIntersil Sigma Delta Calibration
Techniqueâ
- Application Note, AN9505 âUsing the HI7190 Evaluation
Kitâ
- Technical Brief, TB331 âUsing the HI7190 Serial
Interfaceâ
- Application Note, AN9527 âInterfacing HI7190 to a
Microcontrollerâ
- Application Note, AN9532 âUsing HI7190 in a
Multiplexed Systemâ
- Application Note, AN9601 âUsing HI7190 with a Single
+5V Supplyâ
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright © Intersil Americas Inc. 2003, 2005-2006. All Rights Reserved.
All other trademarks mentioned are the property of their respective owners.
|
▷ |