English
Language : 

SMHF283R3S_15 Datasheet, PDF (8/15 Pages) Interpoint Corporation Company – SMHF Single and Dual DC-DC Converters
Crane Aerospace & Electronics Power Solutions
SMHF Single and Dual DC-DC Converters
16-45 Volt Input – 15 Watt
Table 8: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, unless otherwise specified.
DUAL output models
PARAMETER
CONDITIONS
SMHF2805D
MIN TYP MAX
SMHF2812D
MIN TYP MAX
SMHF2815D
MIN
TYP MAX UNITS
OUTPUT VOLTAGE
OUTPUT CURRENT 2
VIN = 16 to 45 V
OUTPUT POWER 2
VIN = 16 to 45 V
OUTPUT RIPPLE
± VOUT, 10 kHz - 2 MHz
LINE REGULATION 3
VIN = 16 TO 45 V
LOAD REGULATION 3
NO load TO FulL
CROSS REGULATION 4
INPUT VOLTAGE
NO LOAD TO FULL
+VOUT
-VOUT
Either OUTPUT
TOTAL
4.85 5.00 5.15 11.76 12.00 12.24 14.70 15.00 15.30
V
4.82 5.00 5.18 11.70 12.00 12.30 14.63 15.00 15.38
—
±1.2 1.68
— ±0.625 0.875 —
±0.5 0.7
A
—
—
2.4
—
—
1.25
—
—
1.0
Either OUTPUT
TOTAL
—
±6
8.4
—
—
—
12
—
—
10.5
—
—
15
—
—
10.5
W
—
15
TC = 25°C
­—
TC = -55°C TO +125°C ­—
+VOUT
—
-VOUT
—
+VOUT
—
-VOUT
—
EFFECT ON -VOUT
—
CONTINUOUS
16
TRANSIENT 50 ms 1
—
30
95
—
30
95
—
2
10
—
10
100
—
5
25
—
80
150
—
6
7.5
—
28
45
16
—
50
—
30
95
—
30
95
—
2
18
—
10
100
—
5
25
—
60
150
—
3
6
—
28
45
16
—
50
—
30
95 mV p-p
30
95
2
18
mV
10
100
5
25
mV
40
150
3
6
%
28
45
V
—
50
V
INPUT CURRENT
NO LOAD
INHIBITED
—
25
50
—
30
50
—
30
50
mA
—
6
10
—
6
10
—
6
10
INPUT RIPPLE CURRENT
10 kHz - 10 MHz
—
60
120
—
55
120
—
55
120 mA p-p
EFFICIENCY
LOAD FAULT 5
TC = 25°C
75
77
—
76
80
—
76
82
—
%
TC = -55°C TO +125°C
72
—
—
74
—
—
74
—
—
POWER DISSIPATION —
3
6
—
3
6
—
3
6
W
SHORT CIRCUIT
RECOVERY 1
—
6
30
—
6
50
—
6
50
ms
STEP LOAD RESPONSE 6, 7, 8 TRANSIENT
— ±200 ±500
—
±300 ±600
—
±300 ±600 mV pk
50% - 100% - 50% Bal Loads
STEP LINE RESPONSE 1, 6, 9
RECOVERY
TRANSIENT
—
90
400
—
90
400
—
90
400
µs
— ±500 ±800
—
±500 ±750
—
±550 ±750 mV pk
± VOUT, 16 - 40 - 16 V
STEP LINE RESPONSE 1, 6, 9
RECOVERY
TRANSIENT
—
200 700
—
300
900
—
300 900
µs
— ±125 —
—
±160
—
— ±160 — mV pk
± VOUT, 22 - 32 - 22 V
STEP LINE RESPONSE 1, 6, 9
RECOVERY
TRANSIENT
—
200
—
— ±200 —
—
160
—
—
±250
—
—
160
—
µs
— ±250 — mV pk
± VOUT, 36 - 45 - 36 V
STARTUP 10
RECOVERY
DELAY
—
160
—
12
OVERSHOOT 1
0
100
CAPACITIVE LOAD 11
TC = 25°C
—
—
Notes
1. Guaranteed by characterization test and/or analysis. Not a production test.
2. Up to 70% of the total output power is available from either output providing the
opposite output is simultaneously carrying 30% of the total output power. Each
output must carry a minimum of 30% of the total output power in order to maintain
regulation on the negative output.
3. Balanced loads.
4. Effect on –Vout for the following conditions, percentages are of total power:
+Po = 50%, –Po = 10%; +Po = 10%, –Po = 50%
+Po = 70%, –Po = 30%; +Po = 30%, –Po = 70%
All conditions are referenced to balanced loads of 50%/50%.
—
—
200
—
—
200
—
µs
25
—
10
20
—
10
20
ms
500
0
100
500
0
100 500 mV pk
47
—
—
10
—
—
10
µF
5. Indefinite short circuit protection not guaranteed above 125°C (case)
6. Recovery time is measured from application of the transient to point at which
Vout is within regulation.
7. Response of either output with the opposite output held at half of the total output
power.
8. Step transition time >10 µs.
9. Step transition time 100 µs ±20%.
10. Tested on release from inhibit.
11. Applies to each output.
www.craneae.com/interpoint
Page 8 of 15
SMHF Rev AF - 2015.10.28