FMD28-461_14 Datasheet, PDF (8/8 Pages) Interpoint Corporation Company – EMI Input Filters 28 Volt input – 7 Amp
Crane AerospaCcrean&e EAleercotrsopnaicces P&oEwleecr tSroonluictsionPsower Solutions
QuaFliMtyDA2s8s-4u6ra1nEcMe IaInndpuCteFritlitfeicrastion
28AVPoPlLtICiAnTpIuOtN–N7OATEmp
STandard and /eS (non-Qml) enVironmenTal Screening 1, 2
TeST performed
Pre-cap Inspection
Method 2017, 2032
Temperature Cycle (10 times)
Method 1010, Cond. B, -55°C to +125°C, ambient
Constant Acceleration
Method 2001, 500 g
Burn-in
Method 1015 3
96 hours
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip
Final visual inspection
Method 2009
non-Qml
STandard
/eS
n
n
n
n
n
n
n
n
n
n
n
n
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. “Non-QML” Refers to products that do not offer QML screening.
2. Standard and /ES, non-QML products, may not meet all of the requirements of MIL-PRF-38534.
3. Burn-in temperature designed to bring the case temperature to the maximum case temperature of the product. Refer to the specific
product information for the maximum case temperature. Burn-in is a powered test.
Table 6: Environmental Screening
taBle 7: envIROnMental scReenIng–hIgh RelIaBIlIty standaRd and /es, nOn-QMl
wFMwDw2.c8r-4a6n1eaEeM.IcIonmpu/tinFtieltreprso,inFtMD28 Rev