English
Language : 

MFK281R8S Datasheet, PDF (6/23 Pages) Interpoint Corporation Company – MFK S ingle and D ual D C-DC Converters 16 to 50 vol ts i npu t – 25 Watt
Crane Aerospace & Electronics Power Solutions
MFK Single and Dual DC-DC Converters
162t8o V50ovltoilntps uintp–ut25– 2W5 Watattt
Table 6: Electrical Characteristics -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT 2
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
INPUT RIPPLE CURRENT
EFFICIENCY
LOAD FAULT 3, 4
SHORT CIRCUIT
STEP LOAD RESPONSE 5, 6
50% - 100% - 50%
STEP LINE Response 1, 5, 7
16 - 50 - 16 V
START-UP 8
FULL LOAD
CAPACITIVE LOAD 1
TC = 25°C
CONDITIONS
VIN = 16 TO 50
VIN = 16 TO 50
TC = 25°C
TC = -55°C TO +125°C
VIN = 16 TO 50
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 1 sec.1
NO LOAD
INHIBITED
10 kHz - 20 MHz
TC = 25°C
TC = -55°C TO +125°C
POWER DISSIPATION
RECOVERY 1
TRANSIENT
RECOVERY
TRANSIENT
RECOVERY
DELAY
OVERSHOOT 1
NO EFFECT ON DC
PERFORMANCE
MFK281R8S
MIN TYP MAX
1.74 1.80 1.86
—
—
5.56
—
—
10
—
30
60
—
35
80
—
5
20
—
10
25
16
28
50
—
—
65
—
25
50
—
2.5
4
—
30
75
69
72
—
67
—
—
—
—
8.5
—
—
20
—
125 200
—
2­ 00 400
—
—
350
—
0.5
1
—
—
25
—
—
50
—
— 2000
MFK282R5S
MIN TYP MAX
2.42 2.50 2.58
—
—
5.0
—
—
12.5
—
30
60
—
35
80
—
5
20
—
5
25
16
28
50
—
—
65
—
25
50
—
2.5
4
—
30
80
73
76
—
71
—
—
—
—
8.5
—
—
20
—
125 200
—
100 300
—
—
350
—
0.5
1
—
—
25
—
—
50
—
— 2000
MFK283R3S
MIN TYP MAX
3.20 3.30 3.40
—
—
4.55
—
—
15
—
25
60
—
30
80
—
5
20
—
5
25
16
28
50
—
—
65
—
25
50
—
2.5
4
—
30
80
76
79
—
74
—
—
—
—
8.5
—
—
20
—
125 200
—
200 300
—
—
350
—
0.5
1
—
—
25
—
—
50
UNITS
V
A
W
mV p-p
mV
mV
V
V
mA
mA p-p
%
W
ms
mV pk
µs
mV pk
ms
ms
mV pk
—
—
2000
µF
Notes
1. Guaranteed by characterization test and/or analysis. Not a production test.
2. A minimum load of 20% is recommended.
3. Short circuit measured with 1% 10 milliohm resistive load.
4. Indefinite short circuit protection not guaranteed above 125°C.
5. Recovery and startup times are measured from application of the transient or
change in condition to the point at which VOUT is within 1% of final value. CL = 0.
6. Step load transition time 10 µs ±1 µs.
7. Step line transition time 100 µs ±20 µs.
8. Tested on release from inhibit.
www.craneae.com/interpoint
Page 6 of 23
MFK Rev AJ - 2016.04.25