MFK281R8S Datasheet, PDF (4/23 Pages) Interpoint Corporation Company – MFK S ingle and D ual D C-DC Converters 16 to 50 vol ts i npu t – 25 Watt
Crane Aerospace & Electronics Power Solutions
MFK Single and Dual DC-DC Converters
162t8o V50ovltoilntps uintp–ut25– 2W5 Watattt
model numbering key
Base Model
MFK 28 12 D
Input Voltage
Output Voltage
(R = decimal point, 3R3 = 3.3 Vout)
F / 883
Number of Outputs
(S = single, D = dual)
Case Option
(Non-flanged case has no designator in
this position)
Screening
(Standard screening has no designator
in this position.)
Figure 5: Model Numbering Key
SMD Numbers
Standard Microcircuit Drawing MFK Similar Part
(SMD)
5962-1421001HXC
MFK281R8S/883
5962-1421002HXC
MFK282R5S/883
5962-1421003HXC
MFK283R3S/883
5962-1421004HXC
MFK2805S/883
5962-1421009HXC in process MFK285R2S/883
5962-1421005HXC
MFK285R7S/883
5962-1421006HXC
MFK2812S/883
5962-1421007HXC
MFK2815S/883
5962-1421008HTC
MFK2828S/883
5962-1421101HXC
MFK2805D/883
5962-1421102HXC
MFK2807D/883
5962-1421103HXC
MFK2812D/883
5962-1421104HXC
MFK2815D/883
The SMD number shown is for Class H screening, non-flanged. To
indicate the flanged case option change the “X” to “Z” In the SMD
number (“T” to “U” for 28 single). For exact specifications for an SMD
product, refer to the SMD drawing. SMDs can be downloaded from:
http://www.landandmaritime.dla.mil/programs/smcr
Table 3: SMD Cross Reference
Category
model Number Options
To determine the model number enter one option from
each category in the form below.
Base Model and
Input Voltage
Output Voltage 1
Number of
Outputs 2
Case Options 3
Screening 4
Options
MFK28
1R8, 2R5, 3R3, 05
5R2, 5R7, 12, 15, 28
05, 07, 12, 15
S
(non-flanged, leave blank)
(standard, leave blank)
D
F (flanged)
ES
883
Fill in for
Model #
MFK28
/
Notes
1. Output Voltage: An R indicates a decimal point. 1R8 is 1.8 volts out. The values of 1.8, 2.5, 3.3 and 5.7 volts are only available in single output models.
2. Number of Outputs: S is a single output and D is a dual output.
3. Case Options: For the standard case, Figure 32 on page 18 or Figure 33 on page 19, leave the case option blank. For the flanged case option, Figure 34 on
page 20 or Figure 35 on page 21, insert the letter F in the Case Option position.
4. Screening: For standard screening leave the screening option blank. For other screening options, insert the desired screening level. For more information see
Table 11 on page 22 and Table 12 on page 23.
Table 4: Model Number Options
www.craneae.com/interpoint
Page 4 of 23
MFK Rev AJ - 2016.04.25