English
Language : 

HR120 Datasheet, PDF (3/6 Pages) Interpoint Corporation Company – –40°C to +85°C operation 50 V for up to 50 ms transient protection
DC/DC Converters
hr120
series
12 Watt
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
single output models
PARAMETER
CONDITIONS
output voltage
output current
output power
output ripple
min to max vin
10 kHz to 2 MHz
line regulation
load regulation
min to max vin
no load to full
input voltage
no load to full
transient 50 ms
input current
no load
full load
inhibited
input ripple current
10 kHz to 2 MHz
efficiency
load fault1
power dissipation
overload
short circuit
start-up
delay
hr121-2805
hr121-2812
hr121-2815
MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95 5.0 5.05 11.88 12 12.12 14.85 15 15.15
—
—
2.0 —
—
1.0 —
—
0.8
—
—
10 —
—
12 —
—
12
—
40
60 —
30
60 —
25
50
—
10
50 —
10
50 —
10
50
—
10
50 —
10
50 —
10
50
16
28
40 16
28
40 16
28
40
—
—
50 —
—
50 —
—
50
—
20
30 —
20
30 —
20
30
—
—
478 —
—
548 —
—
535
—
2
3—
2
3—
2
3
—
135
180 —
150
200 —
150
220
74
77
— 77
81
— 80
83
—
—
—
5—
—
—
3.5 —
— 180 300 —
—
5—
—
2.8 —
80
200 —
—
5
—
2
150
250
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
mA
mA p-p
%
W
ms
Notes
1.Applies to both outputs.
2.Maximum combined output power is 12 watts. A maximum of 90% is
available from either output.
3.20% to 80% load on the positive output and 80% to 20% on the
negative output. See Figure 8.
4.50% load on the positive output and 50% to 20% load on the nega-
tive output. 50% load on the negative output and
50% to 20% load on the positive output. See Figure 7.
5.Indefinite short circuit protection not guaranteed above 85°C case
temperature.
pin out
Pin Single Output Dual Output
1 Inhibit Inhibit
2 No connection Positive Output
3 Output Common Output Common
4 Positive Output Negative Output
5 No connection No connection
6 Case Ground Case Ground
7 Input Common Input Common
8 Positive Input Positive Input
Squared corner and dot on
top of cover indicate pin one.
1
2345
BOTTOM VIEW
HR120
8
7
6
See case E1 for dimensions
Figure 1: Pin Out
model number key
Base Model
Number of Outputs
(1 = single, 2 = dual)
HR12 2 - 28 12
Input Voltage
Output Voltage
www.interpoint.com
Page 3 of 6
HR120 Rev C - 20090904