English
Language : 

FMCE-0328 Datasheet, PDF (10/10 Pages) Interpoint Corporation Company – Attenuation to 60 db at 500 kHz, typical Operating temperature -55° to +125°C
Crane Aerospace & Electronics Power Solutions
FMCE-0328 EMI Input Filter
28 Volt Input – 3 Amp
STANDARD AND /ES (NON-QML) AND /883 (CLASS H, QML)
PRODUCT ENVIRONMENTAL SCREENING
test perFOrmed
Pre-cap Inspection
Method 2017, 2032
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 1010, Cond. B, -55°C to 125°C, ambient
Constant Acceleration
Method 2001, 3000 g
Method 2001, 500 g
Burn-in 2
Method 1015, 125°C case, typical
96 hours
160 hours
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
Subgroups 1 and 4: +25°C case
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10-3)
Final visual inspection
Method 2009
125°C standard
nOn-Qml1
yes
no
no
no
no
no
no
no
yes
no
no
yes
yes
125°C /es
nOn-Qml1
yes
no
yes
no
yes
/883
Class h Qml
yes
yes
no
yes
no
yes
no
no
yes
no
yes
yes
no
yes
yes
yes
yes
no
no
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. Standard and /ES, non-QML products, do not meet all of the requirements of MIL-PRF-38534.
2. Burn-in temperature designed to bring the case temperature to +125°C
Screening Table 2: Environmental Screening
FMCE-0328 EMI Input Filter, FMCE-0328 Rev D - 20100413. This revision supersedes all previous releases. All technical information is believed
to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications
without notice. FMCE-0328 is a trademark of Interpoint. Copyright © 1999 - 2010 Interpoint Corporation. All rights reserved. www.interpoint.com
Page 10 of 10