English
Language : 

TLE6288R_10 Datasheet, PDF (9/32 Pages) Infineon Technologies AG – Smart 6 Channel Peak & Hold Switch
TLE6288R
General Product Characteristics
Attention: Integrated protection functions are designed to prevent IC destruction under fault conditions
described in the data sheet. Fault conditions are considered as “outside” normal operating
range. Protection functions are not designed for continuous repetitive operation.
40V
10 times
(once/ 30sec)
12V
160ms
350ms
Figure 3 Test Condition
3.2
Thermal Resistance
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
3.2.1
–
3.2.2
3.2.3
Junction to Case1)
Junction to ambient1)
RthjC
RthjA
1
15.5
K/W 2)
K/W 2) 3)
1) Not subject to production test, specified by design.
2) Channel 1-6 continously turned on, 0.8W power dissipation per channel
3) Specified RthjA value is according to Jedec JESD51-2,-5,-7 at natural convection on FR4 2s2p board ; The Product
(Chip+Package) was simulated on a 76.2 x 114.3 x 1.5 mm board with 2 inner copper layers (2 x 70μm Cu, 2 x 35μm Cu).
Where applicable a thermal via array under the exposed pad contacted the first inner copper layer.
Further informations can be found in Chapter 7.2
Data Sheet
9
Rev. 2.5, 2010-10-11