TLE6208-3-G Datasheet, PDF (9/21 Pages) Infineon Technologies AG – Triple-Half-Bridge | |||
|
◁ |
TLE 6208-3 G
2.2
Operating Range
Parameter
Symbol Limit Values Unit
min. max.
Supply voltage
VS
VUV OFF 40
V
Supply voltage slew rate
Logic supply voltage
Supply voltage increasing
Supply voltage decreasing
Logic input voltage (DI, CLK,
CSN, INH)
SPI clock frequency
Junction temperature
dVS /dt
VCC
VS
VS
VI
fCLK
Tj
â
4.75
â 0.3
â 0.3
â 0.3
â
â 40
10
V/µs
5.50 V
VUV ON V
V V UV OFF
VCC
V
1
MHz
150 °C
Remarks
After VS rising
above VUV ON
â
â
Outputs in tristate
Outputs in tristate
â
â
â
Thermal Resistances
Junction pin
Junction ambient
Rthj-pin
â
RthjA
â
30
K/W measured to
pin 1, 7, 8, 14
65
K/W â
Note: In the operating range, the functions given in the circuit description are fulfilled.
Data Sheet
9