English
Language : 

TLE4966-3K Datasheet, PDF (9/15 Pages) Infineon Technologies AG – High Sensitivity Automotive Hall Switch with direction detection
TLE4966-3K
Operating Range
Table 3 ESD Protection 1)
Parameter
Symbol
Limit Values Unit Notes
min.
max.
ESD voltage
VESD
–
±4
kV HBM, R = 1.5 kΩ,
C = 100 pF
TA = 25°C
1) Human Body Model (HBM) tests according to: EOS/ESD Association Standard S5.1-1993 and Mil. Std. 883D method
3015.7
4
Operating Range
The following operating conditions must not be exceeded in order to ensure correct operation of the TLE4966-3K.
All parameters specified in the following sections refer to theses operating conditions unless otherwise mentioned.
Table 4 Operating Range
Parameter
Symbol
Limit Values Unit
min. typ. max.
Supply voltage
VDD
VS
VS
Output voltage
VQ
Junction temperature Tj
2.7 –
–
–
–
–
-0.7 –
-40 –
–
–
18 V
24
26
18 V
150 °C
175
Output current
IQ
0
–
10 mA
Conditions
1 h with RS ≥ 200 Ω
for 5 min RS ≥ 200 Ω
for 168 h
Datasheet
9
Rev.1.0, 2010-09-20