ICE2QR0665_10 Datasheet, PDF (8/21 Pages) Infineon Technologies AG – Off-Line SMPS Quasi-Resonant PWM Controller
CoolSET® - Q1
ICE2QR0665
Functional Description
after demagnetisation of the transformer. This value is fixed
according to the feedback voltage, VFB, which contains
information about the output power. Indeed, in a typical peak
current mode control, a high output power results in a high
feedback voltage, and a low output power leads to a low
regulation voltage. Hence, according to VFB, the value in the
up/down counter is changed to vary the power MOSFET off-
time according to the output power. In the following, the
variation of the up/down counter value according to the
feedback voltage is explained.
The feedback voltage VFB is internally compared with three
threshold voltages VRL, VRH and VRM, at each clock period
of 48ms. The up/down counter counts then upward, keep
unchanged or count downward, as shown in Table 1.
Table 1 Operation of the up/down counter
vFB
Always lower than VFBZL
Once higher than VFBZL, but
always lower than VFBZH
Once higher than VFBZH, but
always lower than VFBR1
Once higher than VFBR1
up/down counter
action
Count upwards till 7
Stop counting, no
value changing
Count downwards
till 1
Set up/down counter
to 1
In the ICE2QR0665, the number of zero crossing is limited
to 7. Therefore, the counter varies between 1 and 7, and any
attempt beyond this range is ignored. When VFB exceeds
VFBR1 voltage, the up/down counter is initialised to 1, in
order to allow the system to react rapidly to a sudden load
increase. The up/down counter value is also intialised to 1 at
the start-up, to ensure an efficient maximum load start up.
Figure 5 shows some examples on how up/down counter is
changed according to the feedback voltage over time.
The use of two different thresholds VFBZL and VFBZH to count
upward or downward is to prevent frequency jittereing when
the feedback voltage is close to the threshold point.
However, for a stable operation, these two thresholds must
not be affected by the foldback current limitation (see
Section 3.4.1), which limits the VCS voltage. Hence, to
prevent such situation, the threshold voltages, VFBZL and
VFBZH, are changed internally depending on the line voltage
levels.
clock
T=48ms
t
VFB
VFBR1
VFBZH
VFBZL
Up/down
counter
t
1
Case 1 4 5 6 6 6 6 5 4 3 1
Case 2 2 3 4 4 4 4 3 2 1 1
Case 3 7 7 7 7 7 7 6 5 4 1
Figure 5 Up/down counter operation
3.3.1.2 Zero crossing (ZC counter)
In the system, the voltage from the auxiliary winding is
applied to the zero-crossing pin through a RC network,
which provides a time delay to the voltage from the
auxiliary winding. Internally, this pin is connected to a
clamping network, a zero-crossing detector, an output
overvoltage detector and a ringing suppression time
controller.
During on-state of the power switch a negative voltage
applies to the ZC pin. Through the internal clamping
network, the voltage at the pin is clamped to certain
level.
The ZC counter has a minimum value of 0 and maximum
value of 7. After the internal MOSFET is turned off, every
time when the falling voltage ramp of on ZC pin crosses the
100mV threshold, a zero crossing is detected and ZC counter
will increase by 1. It is reset every time after the DRIVER
output is changed to high.
The voltage vZC is also used for the output overvoltage
protection. Once the voltage at this pin is higher than
the threshold VZCOVP during off-time of the main switch,
the IC is latched off after a fixed blanking time.
To achieve the switch-on at voltage valley, the voltage
from the auxiliary winding is fed to a time delay network
(the RC network consists of Dzc, Rzc1, Rzc2 and Czc as
shown in typical application circuit) before it is applied
to the zero-crossing detector through the ZC pin. The
needed time delay to the main oscillation signal ∆t
should be approximately one fourth of the oscillation
period (by transformer primary inductor and drain-
source capacitor) minus the propagation delay from
Version 2.3
8
April 27, 2010