English
Language : 

TLE6214L_04 Datasheet, PDF (7/22 Pages) Infineon Technologies AG – Smart Dual Current Sense Switch
Datasheet TLE 6214 L
the on/off register are reseted and the current consumption drastically reduced. A wake up is done by
sending a wake up command by SPI. A specified time (twake) after this command the IC is fully func-
tional. The configuraton register (exception channel on/off register) values are not influenced by the
sleep mode. After wake up the outputs are Off, except the outputs are controlled by parallel inputs.
Overload Protection: The IC can be programmed to react in different ways to overload.
Current limit 1: In this mode the IC active limits the current to the specified “Current Limit 1”. If the cur-
rent limitation is active for longer than the fault filtering time this fault is reported and stored in the Fault
register.
Current limit 2: If this current limit is active for more than the specified “Overload switch off delay time”
the affected channel is turned off and the fault is reported and stored in the fault register. To turn on the
channel again this overload latch has to be reset before with an L! H transition of the input signal
(parallel /SPI depending on the programmed operation).
The two operation modes can be changed during operation of the channel.
Pin description:
OUTPUT 1,2 – Drain pins of the two channels. Output pins and connected to the load.
GND – Ground pins.
IN 1,2 – Parallel Input Pins of the two channels
IS / Fault / ST1 –Configurable output pin. Depending on the configuration (done by SPI command) it
has three basic functions:
a) General Fault pin. This is a general fault pin (open drain) which shows a high to low transi-
tion as soon as an error is latched into the diagnosis register. When the diagnosis register is
cleared this flag is also reset (high state). This fault indication can be used to generate a µC
interrupt.
b) Sense Function. In this configuration the analog output signal represents the value of the
load current: Sense Current proportional load current channel 1
Sense Current proportional load current channel 2
Sense Current proportional load current of both channels (ID1 + ID2)
c) Status Output for channel 1: The Status output shows the same level as the input signal of
channel 1 as long as there is no error and the inverted input signal when any kind of error
occurs at channel 1
VS – Logic Supply pin. Used to supply the integrated circuitry.
CS – Chip Select of the SPI (low active)
SO / ST2 – Configurable output pin. Depending on the configuration (done by SPI command) it has two
functions:
a) Signal Output of the Serial Peripheral Interface
b) Status Output for channel 2: The Status output shows the same level as the input signal of
channel 2 as long as there is no error and the inverted input signal when any kind of error
occurs at channel 2
SI – Signal Input of the Serial Peripheral Interface. The pin has an internal pull down structure.
SCKL – Clock Input of the Serial Peripheral Interface. The pin has an internal pull down structure
V3.0
Page 7
18.10.2004