English
Language : 

TLE6365G Datasheet, PDF (6/17 Pages) Infineon Technologies AG – Step Down Voltage-Regulator with Reset
TLE 6365
1.6
Electrical Characteristics
8V< VS < 35V; 4.75V< VCC <5.25V; - 40°C< Tj <150°C; RR=47kΩ;
all voltages with respect to ground; positive current defined flowing into the pin; unless otherwise specified
No. Parameter
Symbol Limit Values Unit Test
min. typ. max
Condition
.
1.6.1 Current Consumption
1.6.1.1 Current consumption;
IS
see applicatiopn circuit
1.5 4
1.6.1.2 Current consumption;
IS
see applicatiopn circuit
5 10
1.6.2 Under- and Over-Voltage Lockout at VS
mA ICC=0mA
mA ICC=400mA
1.6.2.1 UV ON voltage;
buck conv. ON
1.6.2.2 UV OFF voltage;
buck conv. OFF
1.6.2.3 UV Hysteresis voltage
VSUVON 4.0 4.5 5.0 V
VSUVOFF 3.5 4.0 4.5 V
VSUVHY 0.2 0.5 1.0 V
1.6.2.4 OV OFF voltage;
buck conv. OFF
1.6.2.5 OV ON voltage;
buck conv. ON
1.6.2.6 OV Hysteresis voltage
VSOVOFF 34 37 40 V
VSOVON 30 33 36 V
VSUVHY 1.5 4
10 V
1.6.3 Over-Voltage Lockout at VCC
VS
increasing;
VS
decreasing
HY = ON -
OFF
VS
increasing
VS
decreasing
HY = OFF -
ON
1.6.3.1 OV OFF voltage;
buck conv. OFF
1.6.3.2 OV ON voltage;
buck conv. ON
1.6.3.3 OV Hysteresis voltage
VCCOVOFF 5.5 6.0 6.5 V
VCCOVON 5.25 5.75 6.25 V
VCCOVHY 0.10 0.25 0.50 V
VCC
increasing
VCC
decreasing
HY = OFF -
ON
Data Sheet Rev. 1.7
6
2003-06-02