English
Language : 

TLE75080-EMD Datasheet, PDF (48/67 Pages) Infineon Technologies AG – SPI Driver for Enhanced Relay Control
9.3
Electrical Characteristics Diagnosis
TLE75080-EMD
Diagnosis
Table 11 Electrical Characteristics Diagnosis
VDD = 3 V to 5.5 V, VS = 7 V to 18 V, TJ = -40 °C to +150 °C (unless otherwise specified)
Typical values: VDD = 5 V, VS = 13.5 V, TJ = 25 °C
Parameter
Symbol
Values
Unit Note /
Min. Typ. Max.
Test Condition
Output Status Monitor
Output Status Monitor
tOSM
comparator settling time
–
–
20
µs
1)
Output Status Monitor
threshold voltage
VOUT(OL)
3
3.3
3.6
V
2)
Output diagnosis current
IOL
70
85
100 µA
VOUT = 3.3 V
Open Load equivalent
ROL
resistance
30
–
300
kΩ
1)
1) Not subject to production test - specified by design
2) Output status detection voltages are referenced to ground (GND pin)
Number
P_9.5.1
P_9.5.3
P_9.5.5
P_9.5.6
Data Sheet
48