English
Language : 

TLD5190QV Datasheet, PDF (44/58 Pages) Infineon Technologies AG – H-Bridge DC/DC Controller for High Power LED Lighting
10.7
Electrical Characteristics
H-Bridge DC/DC Controller
TLD5190QV
Protection and Diagnostic Functions
Table 10 EC Protection and Diagnosis
VIN = 8V to 36V, Tj = -40°C to +150°C, all voltages with respect to AGND; (unless otherwise specified)
Parameter
Symbol
Values
Unit Note / Test Condition Number
Min. Typ. Max.
Short Circuit Protection
Short to GND
threshold
VVFB_S2G
0.53 0.563 0.59 V
VVFB decreasing;
P_10.8.1
Temperature Protection:
Over Temperature Tj,SD
Shutdown
Over Temperature
Shutdown
Hysteresis
Tj,SD,hyst
160
175
190
°C
1)
–
10
–
°C
1)
P_10.8.4
P_10.8.5
Overvoltage Protection:
VFB Over Voltage
Feedback
Threshold
VVFB_OVTH
1.42
1.46
1.50 V
P_10.8.6
Output Over
VVFB_OVTH,HY 25
40
58
mV Output Voltage
Voltage Feedback S
decreasing;
Hysteresis
P_10.8.7
Open Load and Open Feedback Diagnostics
Open Load rising
Threshold
VVFB_OL,rise
1.29
1.34
1.39 V
VFBH-FBL = 0 V;
P_10.8.9
Open Load
reference Voltage
VFBH-FBL
Open Load falling
Threshold
VFBH_FBL_OL
VVFB_OL,fall
–
1.23
15
1.28
22.5 mV VFB = 1.4 V;
1.33 V
VFBH-FBL = 0 V;
P_10.8.10
P_10.8.11
Input Overvoltage protection
Input Overvoltage VINOVLOth
1.9
2
rising Threshold
2.1
V
–
P_10.8.12
Input Overvoltage VINOVLO(hyst) 18
40
62
mV –
Threshold
Hysteresis
P_10.8.13
Error Flags
EF1,2 Pin Output
Impedance
REF12
–
2.1
–
kΩ
1)Fault Condition
I=100uA
P_10.8.14
1) Specified by design; not subject to production test.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
Data Sheet
44
Rev. 1.0, 2016-05-20