TLE4998C3C Datasheet, PDF (37/42 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4998C3C
SPC Output Definition
12.4
Synchronous Transmission
In the “synchronous” mode, the sensor (slave) starts to transfer a complete data frame
only after a low pulse is forced by the master on the OUT pin. This means that the data
line is bidirectional - an open drain output of the microcontroller (master) sends the
trigger pulse. The sensor then initiates a sync pulse and starts to calculate the new
output data value. After the synchronization period, the data follows in form of a standard
SENT frame, starting with the status, data and CRC nibbles. At the end, an end pulse
allows the CRC nibble decoding and indicates that the data line is idle again. The timing
diagram in Figure 11 visualizes a synchronous transmission.
Table 24 Master Pulse Timing Requirements for Synchronous Mode
Parameter
Symbol
Limit Values Unit1) Notes
min. typ. max.
Master low time
tmlow
1.5 2.75 4
UT
1) UT = Programmed nominal SPC unit time
Sensor
VDD
OUT
GND
CPU
Capcom-Unit
Outpin (OD)
Figure 13 Bidirectional Communication in Synchronous Mode
12.5
Synchronous Transmission Including Range Selection
The low time duration of the master can be used to select the magnetic range of the
sensor in SPC dynamic range selection mode.
Table 25 Master Pulse Timing Requirements for Dynamic Range Mode
Parameter
Master low time
Symbol
tmlow
Limit Values Unit1) Notes
min. typ. max.
1.5 3.25 5
UT Range = 200mT (R=0)
9
12 15 UT Range = 100mT (R=1)
24 31.5 39 UT Range = 50mT (R=3)
1) UT = Programmed nominal SPC unit time
Data Sheet
37
Rev 1.1, 2009-09