English
Language : 

TDA5200 Datasheet, PDF (35/43 Pages) Infineon Technologies AG – ASK Single Conversion Receiver
TDA 5200
Reference
Table 5-3 AC/DC Characteristics with TA 25 °C, VVCC = 4.5 ... 5.5 V (continued)
Parameter
Symbol
Limit Values
Unit Test Conditions
min
typ
max
PLL
Signal LF (PIN 15)
1 Tuning voltage relative to
VTUNE
0.4
1.6
2.4
V
Vs
L Item
POWER DOWN MODE
Signal PDWN (PIN 27)
1 Powerdown Mode On
PWDNO
0
N
0.8
V
2 Powerdown Mode Off
PWDNOff 2.8
VS
V
3 Input bias current PDWN
IPDWN
t.b.d.
µA
4 Start-up Time until valid IF
TSU
signal is detected
1
ms
VCO MULTIPLEXER
Signal FSEL (PIN 11)
1 fRF range 434 MHz
2 fRF range 869 MHz
3 Input bias current FSEL
VFSEL
1.4
VFSEL
0
IFSEL
200
4
V or open
0.2
V
µA FSEL tied to GND
PLL DIVIDER
Signal CSEL (PIN 16)
1 fCRSTL range 6.xxMHz
2 fCRSTL range 13.xxMHz
VCSEL
1.4
VCSEL
0
4
V or open
0.2
V
3 Input bias current CSEL
ICSEL
5
Measured only in lab.
µA CSEL tied to GND
Wireless Components
5-8
Specification, March 2000