English
Language : 

BTS5562E Datasheet, PDF (34/45 Pages) Infineon Technologies AG – SPI Power Controller
SPOC - BTS5562E
Diagnosis
8.5
Command Description
DCR
Diagnosis Control Register
W/R
RB
ADDR
3
2
1
0
read
1
1
1
SBM
MUX
write
1
1
1
0
MUX
Input Level Field Bits
OUT.OUTn
L/0
MUX 2:0
(OFF-state)
SBM 3
H/1
MUX 2:0
(ON-state)
SBM 3
1) Invalid in stand-by mode
Type
rw
r
rw
r
Description
Set Current Sense Multiplexer Configuration
000 IS pin is high impedance
001 IS pin is high impedance
010 IS pin is high impedance
011 IS pin is high impedance
100 IS pin is high impedance
101 IS pin is high impedance
110 IS pin is high impedance
111 Stand-by mode (IS pin is high impedance)
Switch Bypass Monitor1)
0
VDS < VDS(SB)
1
VDS > VDS(SB)
Set Current Sense Multiplexer Configuration
000 current sense of channel 0 is routed to IS pin
001 current sense of channel 1 is routed to IS pin
010 current sense of channel 2 is routed to IS pin
011 current sense of channel 3 is routed to IS pin
100 current sense of channel 4 is routed to IS pin
101 IS pin is high impedance
110 IS pin is high impedance
111 Stand-by mode (IS pin is high impedance)
Switch Bypass Monitor1)
0
VDS < VDS(SB)
1
VDS > VDS(SB)
Data Sheet
34
Rev. 1.0, 2008-05-15