SPOC - BTS5562E
Diagnosis
Current Sense Multiplexer
There is a current sense multiplexer implemented in the SPOC - BTS5562E that routes the sense current of the
selected channel to the diagnosis pin IS. The channel is selected via SPI register DCR.MUX. The sense current
also can be disabled by SPI register DCR.MUX. For details on timing of the current sense multiplexer, please refer
to Figure 16.
CS
DCR.MUX 110 000
001
110
I
IS
t
sIS (E N)
t
t
t
s IS (MUX )
dIS (MUX )
Figure 16 Timing of Current Sense Multiplexer
t
MuxTiming.emf
8.3
Switch Bypass Diagnosis
To detect short circuit to VBB, there is a switch bypass monitor implemented. In case of short circuit between the
output pin OUT and VBB in ON-state, the current will flow through the power transistor as well as through the short
circuit (bypass) with undefined ratio. As a result, the current sense signal will show lower values than expected by
the load current. In OFF-state, the output voltage will stay close to VBB potential which means a small VDS.
The switch bypass monitor compares the voltage VDS across the power transistor of that channel which is selected
by the current sense multiplexer (DCR.MUX) with threshold VDS(SB). The result of comparison can be read in SPI
register DCR.SBM.
Data Sheet
31
Rev. 1.0, 2008-05-15