English
Language : 

TLD5095EL_15 Datasheet, PDF (25/35 Pages) Infineon Technologies AG – Multitopology LITIX Power DC/DC Controller IC
Infineon® LITIX™ Power
TLD5095EL
Protection and Diagnostic Functions
9.2
Electrical Characteristics
VIN = 6 V to 40 V; 4.5V ≤ VFBH ≤ 40V, 4.5V ≤ VFBL ≤ 40V, Tj = -40°C to +150°C, all voltages with respect to ground,
positive current flowing into pin; (unless otherwise specified)
Table 9-1 Electrical Characteristics
Parameter
Symbol
Values
Min.
Typ. Max.
Status Output
Status Output
Voltage Low
VST,LOW
–
–
0.4
Status Sink Current IST,MAX
2
Limit
–
–
Status Output
Current
IST,HIGH
–
–
1
Status Delay Time tSD
8
Temperature Protection
10
12
Overtemperature Tj,SD
160
175
190
Shutdown
Overtemperature
Tj,SD,HYST
–
Shutdown
Hystereses
15
–
Overvoltage Protection
Output Over Voltage VOVFB,TH
1.21
Feedback Threshold
Increasing
1.25 1.29
Output Over Voltage VOVFB,HYS 50
Feedback Hysteresis
–
150
Over Voltage
Reaction Time
tOVPRR
2
–
10
Over Voltage
IOVFB
-1
Feedback Input
Current
0.1
1
Open Load and Open Feedback Diagnostics
Open Load/Feedback VREF,1,3
-100
–
-20
Threshold
Open Feedback
VREF,2
0.5
–
1
Threshold
Unit Note or
Test Condition
Number
V
IST = 1mA
mA VST = 1V
µA
VST = 5V
ms
°C
°C
P_9.2.1
P_9.2.2
P_9.2.3
P_9.2.4
P_9.2.5
P_9.2.6
V
P_9.2.7
mV Output Voltage
decreasing
µs Output Voltage
decreasing
µA
VOVFB = 1.25 V
P_9.2.8
P_9.2.9
P_9.2.10
mV VREF = VFBH - VFBL P_9.2.11
Open Circuit 1 or 3
V
VREF = VFBH - VFBL P_9.2.12
Open Circuit 2
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in
the data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions
are not designed for continuous repetitive operation.
Data Sheet
25
Revision 1.4