|
TLE4699 Datasheet, PDF (23/31 Pages) Infineon Technologies AG – Low Drop Out Linear Voltage Regulator 5 V Fixed Output Voltage | |||
|
◁ |
TLE4699
Reset Function
8.2
Electrical Characteristics Reset Function
Electrical Characteristics: Reset Function
VI = 13.5 V, Tj = -40 °C to +150 °C,
all voltages with respect to ground, direction of currents as shown in Figure 7 (unless otherwise specified).
Pos. Parameter
Symbol
Limit Values Unit Conditions
Min. Typ. Max.
Output Undervoltage Reset Comparator Default Values (Pin RADJ = GND)
8.2.1
Output Undervoltage Reset VRT,lo
Lower Switching Threshold
4.6 4.7 4.8 V
VI = 0 V
VQ decreasing
RADJ = GND
8.2.2
Output Undervoltage Reset VRT,hi
Upper Switching Threshold
4.7 4.8 4.9 V
VI within operating range
VQ increasing
RADJ = GND
8.2.3
Output Undervoltage Reset VRT,hy
Switching Hysteresis
60 120 â
mV VI within operating range
RADJ = GND.
8.2.4
Output Undervoltage Reset VRH
Headroom
250 300 â
mV Calculated Value:
VQ - VRT,lo
VI within operating range
IQ = 50 mA
RADJ = GND
Reset Threshold Adjustment
8.2.5
Reset Adjust
Lower Switching Threshold
8.2.6 Reset Adjustment Range 1)
Reset Output RO
VRADJ,th
VRT,range
1.17 1.195 1.22 V
3.20 â
4.70 V
VI = 0 V
3.2 V ⤠VQ < 5 V
â
8.2.7 Reset Output Low Voltage VRO,low
8.2.8
8.2.9
Reset Output
External Pull-up Resistor
to Q
Reset Output
Internal Pull-up Resistor
RRO,ext
RRO
â
0.2 0.4 V
VI = 0 V;
1 V ⤠VQ ⤠VRT,low
RRO,ext = 3.3 kΩ
3
â
â
kΩ
VI = 0 V;
1 V ⤠VQ ⤠VRT,low
VRO = 0.4 V
20 30 40 kΩ internally connected to Q
Reset Delay Timing
8.2.10 Upper Delay
Switching Threshold
VDST,hi
â
1.21 â
V
â
8.2.11 Lower Delay
Switching Threshold
VDST,lo
â
0.30 â
V
â
8.2.12 Delay Capacitor
Charge Current
ID,ch
â
3.5 â
μA
VD = 1 V
8.2.13 Delay Capacitor
Reset Discharge Current
IDR,dsch
â
80 â
mA VD = 1 V
8.2.14 Undervoltage Reset Delay
Time
td,100nF
16 23 30 ms Calculated value;
CD = 100 nF 2);
CD discharged to VDST,lo
Data Sheet
23
Rev. 1.0, 2010-11-30
|
▷ |