TLD2326EL_15 Datasheet, PDF (21/30 Pages) Infineon Technologies AG – 3 Channel High Side Current Source
VIN _SET
VIN _SET( OL /SC)
VIN _SET (ref )
VOU T
VF
tSC
tIN_SET( re set)
TLD2326EL
Load Diagnosis
t
VOUT (SC)
t
short circuit
occurs
short circuit
disappears
Figure 14 IN_SET behavior during short circuit to GND condition with ST connected to GND and VDEN >
VDEN(act)
8.3
Double Fault Conditions
The TLD2326EL allows the diagnosis of each channel separately. The diagnosis filter times tOL and tSC (Pos. 8.4.5
and Pos. 8.4.8) are valid only for the channel, which diagnoses first the fault condition. For the other channel or
channels with a subsequential fault the diagnosis is reported immediately without the diagnosis filter time, if the
filter time tOL has been elapsed for the channel with the first fault. During activation via IN_SET of a non-faulty
output, where one channel has already a fault detected, a short spike to VIN_SET(OL/SC) could occur on the channel,
which should be activated. Therefore, in general a diagnosis should be done earliest after the diagnosis filter times
tOL and tSC to avoid any incorrect diagnosis readout. In the scenario mentioned above the turn on time tON(IN_SET)
could be extended. The following figure shows the example behavior, if OUT1 has a fault and OUT2 is operated
in PWM-mode. OUT3 is disabled.
Data Sheet
21
Rev. 1.1, 2015-03-24