Case 2:
The âExtended blanking timeâ feature happened first
and it follows with the âAuto-restart enableâ feature.
Then the âAuto-restart enableâ feature will take the
priority and the âExtended blanking timeâ feature is
overridden.
Case 3:
The âExtended blanking timeâ feature happened first
and it follows with the âBrownoutâ feature. Then the
âExtended blanking timeâ feature will continue to work
until it ends. After that if the over load fault is removed
the âBrownoutâ feature takes the action.
Case 4:
The âBrownoutâ feature happened first and it follows
with the âAuto-restart enableâ feature. Then the
âBrownoutâ feature will continue to work and the âAuto-
restart enableâ feature is ignored.
One typical case happened is that the âExtended
blanking timeâ feature happened first and it follows with
the âBrownoutâ feature. If, however, the over load fault
is removed before the end of the extended blanking
time, the âBrownoutâ feature can take action only after
20ms buffer time.