English
Language : 

TLE42994V33 Datasheet, PDF (18/25 Pages) Infineon Technologies AG – Low Dropout Fixed Voltage Regulator
TLE42994V33
Block Description and Electrical Characteristics
Electrical Characteristics Reset Function
VI = 13.5 V, -40 °C ≤ Tj ≤ 150 °C, all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Output Undervoltage Reset
5.6.1 Default Output Undervoltage Reset VRT
Switching Thresholds
3.00 3.10 3.20 V
VQ decreasing
5.6.2 Output Undervoltage Reset
Headroom
VRH
50
200 300 mV –
Output Undervoltage Reset Threshold Adjustment
5.6.3 Reset Adjust
Switching Threshold
VRADJ,th 1.26 1.36 1.44 V
VQ > 2.5 V
5.6.4 Reset Adjustment Range1)
Reset Output RO
VRT,range 2.50
–
3.10 V
–
5.6.5 Reset Output Low Voltage
VRO,low
–
0.1
0.4
V
1 V ≤ VQ ≤ VRT
no external RRO,ext
5.6.6
Reset Output Internal
Pull-up Resistor to VQ
RRO
10
20
40
kΩ –
5.6.7 Optional Reset Output External
RRO,ext
5.6
–
–
kΩ
1 V ≤ VQ ≤ VRT ;
Pull-up Resistor to VQ
VRO ≤ 0.4 V
Reset Delay Timing
5.6.8
5.6.9
Delay Pin Output Voltage
Power On Reset Delay Time
5.6.10 Upper Delay
Switching Threshold
VD
–
–
5
V
–
trd
36
51
60
ms CD = 100 nF
Calculated Value:
trd = CD * VDU / ID,ch
VDU
–
1.85 –
V
–
5.6.11 Lower Delay
Switching Threshold
VDL
–
0.50 –
V
–
5.6.12 Delay Capacitor
Charge Current
ID,ch
–
3.5
–
µA VD = 1 V
5.6.13 Delay Capacitor
Reset Discharge Current
ID,dch
–
70
–
mA VD = 1 V
5.6.14 Delay Capacitor
Discharge Time
trr,d
–
5.6.15 Internal Reset Reaction Time
trr,int
–
1.7
3.0
µs
Calculated Value:
trr,d = CD*(VDU -
VDL)/ ID,dch
CD = 100 nF
20
25
µs
CD = 0 nF 2)
5.6.16 Reset Reaction Time
trr,total
–
21.7 28
µs Calculated Value:
trr,total = trr,int + trr,d
CD = 100 nF
1) VRT is scaled linearly, in case the Reset Switching Threshold is modified
2) parameter not subject to production test; specified by design
Data Sheet
18
Rev. 1.01, 2010-10-14