English
Language : 

SAK82C900 Datasheet, PDF (18/29 Pages) Infineon Technologies AG – Standalone TwinCAN Controller
82C900
Preliminary
DC Characteristics
Operating Conditions apply.
Table 4
DC Characteristics under Normal Operation Conditions
Parameter
Symbol Limit Values Unit Test Condition
min. max.
Input low voltage
(XTAL1)
VIL
– 0.5 0.3 VDD V –
Input high voltage
(XTAL1)
VIH
0.7 VDD VDD + V –
0.5
Input low voltage
(other pins)
VIL
– 0.5 0.2 VDD V –
– 0.1
Input high voltage
(other pins)
VIH
0.2 VDD VDD + V –
+ 0.9 0.5
Output low voltage 1)
(P0..P7)
VOLP
–
0.45 V IOLP = 5 mA
Output high voltage 1)
(P0..P7)
VOHP
2.4
–
0.9 VDD –
V IOHP = -5 mA
V IOHP = -0.5 mA
Output low voltage
(other pins)
VOL
–
0.45 V IOL = 2.4 mA
Output high voltage 2)
(other pins)
VOH
2.4
–
0.9 VDD –
V IOH = -2.4 mA
V IOH = -0.5 mA
Input leakage current
RESET inactive current 3)
RESET active current
IOZ
IRSTH 4)
IRSTL 5)
–
–
-100
±500
-10
–
nA 0.45V < VIN < VDD
µA VIN = VIH
µA VIN = VIL
XTAL1 input current
Pin capacitance 6)
(digital inputs/outputs)
IIL
–
CIO
–
±20
µA 0 V < VIN < VDD
10
pF f = 1 MHz
TA = 25 °C
1) The sum of | IOHP |, IOLP must not exceed 20mA.
2) This specification is not valid for outputs which are switched to open drain mode. In this case the respective
output will float and the voltage results from the external circuitry.
3) These parameters describe the RESET pull-up, which equals a resistance of ca. 50 to 250 KΩ.
4) The maximum current may be drawn while the respective signal line remains inactive.
5) The minimum current must be drawn in order to drive the respective signal line active.
6) Not 100% tested, guaranteed by design characterization.
Data Sheet
18
V 1.0D3, 2001-03