TLE7241E Datasheet, PDF (17/71 Pages) Infineon Technologies AG – Dual Channel Constant Current Control Solenoid Driver
TLE 7241E
Functional Description and Electrical Characteristics
OVER-VOLTAGE FAULT
VPOSx - VNEGx
on
LS-Switch
state
off
Vov
Vov-ovhyst
t < tov
Vpwr
14 V
Figure 4 Overvoltage Shutdown
Electrical Characteristics 1)
Tj = -40 to 150 °C; VBAT = 9 V to 18 V; VDD = 4.75 V to 5.25 V
Pos. Parameter
Symbol Limit Values Unit Test Conditions
Min. Typ.2) Max.
and Instructions
5.4.1.1 BAT Overvoltage OV
Shutdown
30 35 40 Vdc Ramp up BAT until
outputs Off
5.4.1.2 BAT Overvoltage OVHYST –
hysteresis
1.0 –
Vdc Ramp BAT down
until outputs On3)
5.4.1.3 OUTx Active
Vclamp 50 53
60
V Id = 20 mA, output
Clamp Voltage
off
1) Positive current flow is into the device.
2) TJ = 25 °C
3) Not subject to production test, specified by design.
5.4.2 Overcurrent / Short to VBAT Sensing
An overcurrent fault is detected by sensing the voltage at the POS input pin. A
comparator is used to detect the voltage while the gate drive is on. When the voltage at
the POS input pin exceeds the short circuit / overcurrent threshold (see table below,
Item 5.4.2.3) for a time greater than the short sense time (see table below, Item 5.4.2.1)