English
Language : 

TLE4990 Datasheet, PDF (17/24 Pages) Infineon Technologies AG – Programmable Linear Output Hall Sensor
TLE4990
Programmable Linear Hall Sensor
Error Detection
7
Error Detection
Broken supply lines can be detected by the OBD (On Board Diagnostics) and reported
to the µController.
Note: The OBD is only useful when the clamping function is enabled.
In the case of interrupted supply lines, the µController may warn the user.
If two sensors are placed in parallel, the output of the remaining working sensor may be
still used for an emergency operation.
Table 12 Open Circuit (OBD parameters)
Parameter
Symbol Limit Values
Unit Notes
Output voltage
@ Open VDD line
Output voltage
@ Open VSS line
1) With RL ≥ 7 kΩ
VOUT
VOUT
min.
0
94
max.
6
100
% VDD 1)
% VDD 1)
Data Sheet
17
V 2.0, 2004-05