English
Language : 

TLE7251V_15 Datasheet, PDF (13/36 Pages) Infineon Technologies AG – High Speed CAN-Transceiver with Bus Wake-up
TLE7251VLE
TLE7251VSJ
Functional Description
4.3.4
Undervoltage on the Digital Supply VIO
If the voltage on VIO supply input falls below the threshold VIO < VIO(UV,F), the transceiver TLE7251V powers down
and changes to the power-down state.
The undervoltage detection on the digital supply VIO has the highest priority. It is independent of the transmitter
supply VCC and also independent of the currently selected operating mode. An undervoltage event on VIO always
powers down the TLE7251V.
transmitter supply voltage VCC = “don’t care”
VIO
VIO undervoltage monitor
VIO(UV,F)
hysteresis
VIO(UV,H)
VIO undervoltage monitor
VIO(UV,R)
tDelay(UV) delay time undervoltage
any mode of operation
power-down state
STB
“X” = don’t care
1) assuming no external signal applied
Figure 6 Undervoltage on the digital supply VIO
t
stand-by mode
“high” due the internal
pull-up resistor1)
t
Data Sheet
13
Rev. 1.0, 2015-09-10