English
Language : 

TLE7251V_15 Datasheet, PDF (11/36 Pages) Infineon Technologies AG – High Speed CAN-Transceiver with Bus Wake-up
TLE7251VLE
TLE7251VSJ
Functional Description
4.3
Power-up and Undervoltage Condition
By detecting an undervoltage event, either on the transmitter supply VCC or the digital supply VIO, the transceiver
TLE7251V changes the mode of operation. Turning off the digital power supply VIO, the transceiver powers down
and remains in the power-down state. While switching off the transmitter supply VCC, the transceiver either
changes to the forced stand-by mode, or remains in stand-by mode (details see Figure 5).
VIO “on”
VCC “on”
STB “0”
normal-operating
mode
STB VCC VIO
0 “on” “on”
power-down
state
STB VCC VIO
“X” “X” “off”
VIO “on”
VCC “off”
STB “0”
VIO “on”
VCC “on”
STB “0”
VIO “on”
VCC “X”
STB “1”
VIO “on”
VCC “X”
STB “1”
Figure 5 Power-up and undervoltage
stand-by
mode
STB VCC VIO
1 “X” “on”
VIO “on”
VCC “off”
STB “0”
VIO “on”
VCC “on”
STB “0”
forced stand-by
mode
STB VCC VIO
0 “off” “on”
VIO “on”
VCC “X”
STB “1”
Table 2 Modes of operation
Mode
STB
VIO
VCC
Bus Bias Transmitter Normal-mode Low-power
Receiver
Receiver
Normal-operating “low”
“on”
“on”
VCC/2
“on”
“on”
“off”
Stand-by
“high”
“on”
“X”
GND
“off”
“off”
“on”
Forced stand-by “low”
“on”
“off”
GND
“off”
“off”
“on”
Power-down state “X”
“off”
“X”
floating “off”
“off”
“off”
Data Sheet
11