English
Language : 

TLE6288R Datasheet, PDF (13/23 Pages) Infineon Technologies AG – Smart 6 Channel Peak&Hold Switch
Preliminary Datasheet TLE6288 R
VCC = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; VB = 6V to 16V ; Reset = H ; VDO = VCC
(unless otherwise specified)
No. Parameter
Sym Condition Value
Unit
bol
min typ max
Pin /
Comment
6 SPI Timing
6.1 Serial Clock Frequency (de-
fSCK
pending on SO load)
6.2 Serial Clock Period (1/fclk)
tp(SCK)
DC -- 5
MHz
200 -- -- ns
6.3 Serial Clock High Time
tSCKH
50 -- -- ns
6.4 Serial Clock Low Time
tSCKL
50 -- -- ns
6.5 Enable Lead Time
tleadL CLKProg=L 200 -- --
ns
(falling edge of CS to falling
edge of SCLK)
Enable Lead Time
(falling edge of CS to rising
edge of SCLK)
tleadH CLKProg=H 200 -- --
ns
6.6 Enable Lag Time (rising edge of tlagL CLKProg=L 200 --- --
ns
SCLK to rising edge of CS )
Enable Lag Time (falling edge tlagH CLKProg=H 200 --- --
ns
of SCLK to rising edge of CS )
6.7 Data Setup Time (required time tSUL CLKProg=L 20 -- --
ns
SI to rising of SCLK)
Data Setup Time (required time tSUH CLKProg=H 20 -- --
ns
SI to falling of SCLK)
6.8 Data Hold Time (rising edge of tHL
CLKProg=L 20 -- --
ns
SCLK to SI)
Data Hold Time (falling edge of tHH CLKProg=H 20 -- --
ns
SCLK to SI)
6.9 Disable Time
tDIS
-- 200 ns
6.10 Transfer Delay Time2
tdt
200 -- -- ns
( CS high time between two
accesses)
6.11 Data Valid Time
tvalid
CL = 50 pF to 100pF
CL = 220 pF
ns
-- -- 120
-- -- 150
1)To get the correct diagnostic information, the transfer delay time has to be extended to the maximum fault delay
time tf(fault)max = 200µs.
Vp2
Page 13
13.01.2003