English
Language : 

TLE6255G Datasheet, PDF (13/23 Pages) Infineon Technologies AG – Single Wire CAN-Transceiver
TLE 6255 G
5.5 V < Vbatt < 16 V; 4.75 V < VCC < 5.25 V; – 40 °C < Tj < 150 °C; M0 = M1 = H;
RUL= 9.1 kΩ (connected between CANH and LOAD); RRSL = 39 kΩ; all voltages with
respect to ground; positive current defined flowing into pin; unless otherwise specified
Parameter
Sym-
Limit Values Unit Test Condition
bol
min. typ. max.
CANH as Bus Input / Receiver
Wake up offset
threshold
VIHWUO Vbatt – –
4.30
Vbatt – V
3.25
Vbatt = 8 V
see note; see Figure 8
Wake up fixed
threshold
VIHWUF 6.15 7.1 8.10 V
Vbatt = 14 V
see note; see Figure 8
Wakeup dead time tDWU 10
Wakeup minimal pulse tWUMIN 1
time
21 50
5 10
µs –
µs –
Receive threshold; in VIH
normal, high-speed
and wake-up mode
1.8 2 2.2 V 6 V < Vbatt < 16 V
Receive hysteresis
Receive propagation
time
Receive propagation
time; high speed
VRHY
tCRF
tCRF
Receive propagation tCRR
time
Receive propagation tCRR
time; high speed
Receive blanking time tCRB
after CANH H to L
transition
50 80 200
0.05 0.3 1
0.05 0.25 0.5
0.05 0.3 1
0.05 0.25 0.5
1.5 3.0 5.0
mV –
µs VCANH > (VIH + 0.8 V) to
RxD = L; 6 V < Vbatt < 16 V
µs VCANH > (VIH + 0.8 V) to
RxD = L; M1 = L;
6 V < Vbatt < 16 V;
Tj < 125 °C
µs VCANH < (VIH – 0.8 V) to
RxD = H; RRxD = 2.4 kΩ
6 V < Vbatt < 16 V
µs VCANH < (VIH – 0.8 V) to
RxD = H; RRxD = 2.4 kΩ
M1 = L; 6 V < Vbatt < 16 V;
Tj < 125 °C
µs see Figure 7
Note: The device will send a wake up call to the microcontroller at the minimum of
VIHWUO or VIHWUF.
Data Sheet Rev. 2.5
13
2003-11-27